Nonthoracotomy- versus thoracotomy-implantable defibrillators. Intention-to-treat comparison of clinical outcomes.

Author:

Kleman J M1,Castle L W1,Kidwell G A1,Maloney J D1,Morant V A1,Trohman R G1,Wilkoff B L1,McCarthy P M1,Pinski S L1

Affiliation:

1. Department of Cardiology, Cleveland Clinic Foundation, OH 44195.

Abstract

BACKGROUND Nonthoracotomy-implantable cardioverter/defibrillator (ICD) systems may represent a significant advance in the treatment of patients with life-threatening ventricular arrhythmias, but their merits relative to those of the well-established thoracotomy systems remain largely unknown. The objective of this study was to compare the short- and long-term clinical outcomes after attempted ICD implantation via a nonthoracotomy versus thoracotomy approach in similar groups of patients. METHODS AND RESULTS Between September 1990 and December 1992, 212 consecutive patients underwent attempted ICD system implantation without concomitant cardiac surgery at a single institution. Approach selection was not randomized but rather was based primarily on hardware availability. Primary comparisons of short- and long-term outcome were performed according to the "intention-to-treat" principle. Implantation was attempted via a nonthoracotomy approach in 120 patients (57%) and via a thoracotomy approach in 92 patients (43%). Prior cardiac surgery was more prevalent in the nonthoracotomy patients; otherwise, groups did not differ significantly in terms of prognostically relevant clinical characteristics. Nonthoracotomy implantation was successful in 101 patients (84%). After crossover to thoracotomy implantation (14 patients), the eventual success rate for ICD system implantation was 96% in the nonthoracotomy group. Thoracotomy implantation was successful in 89 patients (97%). Operative mortality was 3.3% in the nonthoracotomy and 4.3% in the thoracotomy groups (P = .73). Nonthoracotomy group patients were less likely to experience postoperative congestive heart failure (6% versus 16%; P = .02) or supraventricular arrhythmia (6% versus 18%; P = .004) and had significantly shorter postoperative intensive care and total hospitalization. Total hospital costs were significantly lower in the nonthoracotomy group ($32,205 versus $37,265; P = .001). After a follow-up of 16 +/- 9 months, there were 17 deaths in the nonthoracotomy group (none sudden) and 12 deaths in the thoracotomy group (1 sudden). One- and 2-year Kaplan-Meier survival probabilities were .87 (95% CI, .78 to .91) and .80 (95% CI, .68 to .88) in the nonthoracotomy group and .90 (95% CI, .82 to .95) and .87 (95% CI, .77 to .93) in the thoracotomy group (P = .56; log-rank test). CONCLUSIONS Nonthoracotomy ICD implantation is associated with reduced surgical morbidity, postoperative hospital care requirement, and hospital costs and has similar efficacy in preventing sudden death relative to the thoracotomy approach. From these nonrandomized data, it appears that a nonthoracotomy approach should be considered preferable in most patients requiring ICD therapy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 51 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Eligibility for subcutaneous implantable cardioverter defibrillators in the adult congenital heart disease population;Pacing and Clinical Electrophysiology;2018-12-04

2. Cardiac resynchronization therapy: the state of the art;Expert Review of Cardiovascular Therapy;2014-04-22

3. Cardiovascular Implantable Electronic Device Leads in CKD and ESRD Patients: Review and Recommendations for Practice;Seminars in Dialysis;2012-08-15

4. Clinical Trials of Defibrillator Therapy;Clinical Cardiac Pacing, Defibrillation and Resynchronization Therapy;2011

5. Implantation von Kardioverter-Defibrillatoren;Der Anaesthesist;2010-05-12

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3