Cardiovascular Collapse Caused by Electrocardiographically Silent 60-Hz Intracardiac Leakage Current

Author:

Swerdlow Charles D.1,Olson Walter H.1,O’Connor Mark E.1,Gallik Donna M.1,Malkin Robert A.1,Laks Michael1

Affiliation:

1. From the Division of Cardiology, Cedars-Sinai Medical Center, Los Angeles, Calif (C.D.S., D.M.G.); Medtronic Inc, Minneapolis, Minn (W.H.O., M.E.O.); the Joint Department of Biomedical Engineering at The University of Memphis and the University of Tennessee-Memphis, Memphis, Tenn (R.A.M.); and the Division of Cardiology, Harbor-UCLA Medical Center, Torrance, Calif (M.L.).

Abstract

Background —The national standard for safe 60-Hz intracardiac leakage current under a single-fault condition is 50 μA. This standard is intended to protect patients from alternating current (AC) at levels below the threshold for sensation, but the minimum unsafe level for AC in closed-chest humans is not known. To determine this value, we studied 40 patients at testing of implantable cardioverter-defibrillators using a programmable source of 60-Hz AC. Methods and Results —We applied AC for 5-second test periods in increasing strengths until ventricular fibrillation (VF) was induced or 1 mA was reached. Two current paths were tested: bipolar, between tip and ring electrodes of a right ventricular pacing catheter, and unipolar, from tip to a remote electrode. We observed a characteristic sequence of 3 responses as AC was increased: (1) intermittent ventricular capture with QRS morphology identical to pacing through the electrodes (minimum value, 20 μA); (2) continuous capture at cycle length 282±88 ms (minimum value, 32 μA); and (3) VF persisting after AC termination (minimum value, 49 μA). Continuous capture caused loss of pulsatile arterial pressure and cardiovascular collapse (mean arterial pressure, 32±8 mm Hg) for the duration of AC with no ECG evidence of AC stimulation. Thus, the clinical picture was that of hypotensive ventricular tachycardia (VT). The continuous-capture threshold was ≤50 μA in 9 patients (22%) for bipolar AC and in 5 (12%) for unipolar AC. All patients showed continuous capture over a wide range for both bipolar AC (68±18 to 216±238 μA) and unipolar AC (84±27 to 278±226 μA). Conclusions —Leakage current causes cardiovascular collapse at levels below the VF threshold. Stimulation by silent AC that is neither felt nor visible on the ECG presents as hypotensive VT. In patients with intracardiac electrodes, leakage current less than or equal to the present standard of 50 μA may cause VT or VF. The safety standard for leakage current lasting ≥5 seconds should be ≤20 μA. This standard should be based on the continuous-capture threshold.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference25 articles.

1. Association for the Advancement of Medical Instrumentation. American National Standard Safe Current Limits for Electromedical Apparatus . Arlington Va: Association for the Advancement of Medical Instrumentation; 1993. ANSI/AAMI ES1–1993.

2. International Electrotechnical Commission. Medical Electrical Equipment Part 1. General Requirement for Safety . Geneva Switzerland: International Electrotechnical Commission; 1988.

Cited by 50 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3