Intracoronary Heparin Delivery in Humans

Author:

Camenzind Edoardo1,Kint Peter-Paul1,Di Mario Carlo1,Ligthart Jürgen1,van der Giessen Wim1,Boersma Eric1,Serruys Patrick W.1

Affiliation:

1. From the Cardiac Catheterization Laboratory and Intracoronary Imaging Laboratory, Thoraxcenter, University Hospital Dijkzigt, Rotterdam, Netherlands.

Abstract

Background Inefficacy of systemic drug administration for restenosis prevention may partially relate to insufficient local drug concentration. This study aimed to evaluate the acute feasibility and long-term outcome of using an infusion-perfusion coil balloon, Dispatch. Methods and Results In 22 patients after balloon angioplasty, the coil balloon was studied for (1) feasibility of local heparin delivery, (2) symptoms and signs of ischemia during prolonged deployment compared with angioplasty balloon occlusion, (3) coronary pressure and flow distal to the inflated device, and (4) long-term clinical and angiographic results. During prolonged intracoronary deployment of the coil balloon (29±8 minutes), 5 of 22 patients developed mild chest pain versus 20 of 22 during angioplasty (275±283 seconds). Neither hemodynamic nor vectorcardiographic signs of ischemia were detected, in contrast to angioplasty balloon occlusion. Baseline flow across the coil balloon was 44±31 mL/min, increasing by a factor of 1.8±0.7 during pharmacologically induced hyperemia. A mean volume of 14.2±6.1 mL containing 1416±608 IU of heparin was infused locally at a pressure of 122±54 mm Hg. At 7±1-month follow-up, 1 asymptomatic patient had died, and of the remaining 21, 17 (81%) were asymptomatic. Angiographic follow-up was obtained in 15 of 21 patients (71%), including all 4 symptomatic patients. Mean minimal luminal diameter after the procedure was 2.16±0.49 mm and at follow-up, 1.89±0.45 mm, which corresponds to a restenosis rate (diameter stenosis ≥50%) of 7% (1/15). Conclusions Intracoronary use of the coil balloon after balloon angioplasty proved to be feasible and subjectively as well as objectively well tolerated during prolonged deployment by virtue of its perfusion properties. High volumes of heparin solution can be infused locally at very low pressure. No unfavorable clinical or angiographic long-term effects were observed.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3