Endocarditis risk of the USCI PDA umbrella for transcatheter closure of patent ductus arteriosus.

Author:

Latson L A1,McManus B M1,Doer C1,Kilzer K1,Cheatham J P1

Affiliation:

1. Department of Pediatrics and Pathology, University of Nebraska Medical School, Omaha.

Abstract

BACKGROUND The USCI PDA Umbrella is a device to close patent ductus arteriosus (PDA) by a transcatheter technique. Human clinical trials have shown excellent efficacy in reducing or eliminating the PDA shunt, but concerns remain about the risk of infection with this device. The purpose of this study was to evaluate the risk of infection using an animal model. METHODS AND RESULTS Susceptibility to developing endocarditis was tested by injecting a single intravenous dose of group L streptococcus. Ten piglets with a closed ductus served as controls. Two of these developed valvular vegetations. PDA was produced in 19 animals by balloon dilation of the ductus. Seven of 7 animals with PDA at the time of bacterial injection developed endarteritis of the ductus and valvular vegetations. A PDA Umbrella was placed in the remaining 12 animals, and bacteria were injected 2 weeks after device implantation. Infection was evident in the PDA Umbrella only in the single animal in which the Umbrella had embolized and been left in the left pulmonary artery. Three of the remaining 11 piglets had a significant residual leak, and all developed infection in the ductus and an additional valve. Similar to the control group, none of the animals with complete (n = 8) or nearly complete (n = 2) closure of the ductus by the PDA Umbrella had infection in or around the ductus, and only 1 had a valvular vegetation. CONCLUSIONS In this animal model, presence of a significant PDA shunt (with or without a PDA Umbrella present) results in significantly increased susceptibility to endarteritis and endocarditis. The PDA Umbrella device does not appear to be susceptible to direct infection as early as 2 weeks after implantation if it is properly located in the ductus arteriosus. Animals with no shunt or a trivial shunt are no more susceptible to developing endocarditis 2 weeks after PDA Umbrella implantation than are controls.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference12 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3