Detection of Coronary Stenoses and Quantification of the Degree and Spatial Extent of Blood Flow Mismatch During Coronary Hyperemia With Myocardial Contrast Echocardiography

Author:

Ismail Suad1,Jayaweera Ananda R.1,Goodman Norman C.1,Camarano Gustavo P.1,Skyba Danny M.1,Kaul Sanjiv1

Affiliation:

1. From the Cardiovascular Division, University of Virginia School of Medicine, Charlottesville.

Abstract

Background We hypothesized that the degree and spatial extent of blood flow mismatch in beds supplied by stenoses that are not flow-limiting at rest can be quantified with myocardial contrast echocardiography (MCE) using left atrial (LA) and right atrial (RA) injections of contrast during pharmacologically induced coronary hyperemia. Methods and Results In 12 open-chest dogs, MCE was performed and myocardial blood flow (MBF) was measured by use of radiolabeled microspheres at baseline and during phenylephrine-induced coronary hyperemia. In the presence of this drug, stenoses were placed during different stages on the left anterior descending (LAD) and left circumflex (LCx) coronary arteries, and MCE and MBF assessments were performed. LA injections of 2 mL of 0.5 billion/mL microbubbles (mean diameter, 4.3 μm) were performed at each stage in all 12 dogs, and RA injections of 10 mL of 6 billion/mL microbubbles (mean diameter, 3.7 to 5.3 μm) were administered in 7 dogs. MCE images in which the contrast disparity between the LAD and LCx beds was maximal were digitally subtracted from precontrast images, and mean videointensities in these beds were measured after the dynamic range of gray-scale intensities was increased in the subtracted image and the image was color coded. The region showing hypoperfusion during LAD stenosis was planimetered and expressed as a percentage of the myocardial area in the short-axis slice. There was an excellent correlation between the LAD/LCx bed videointensity ratio and LAD/LCx bed MBF ratio ( y =0.5 x +0.44, r =.91, P <.001) during 57 LA injections. There was also an excellent correlation between the hypoperfused bed size on MCE during LA injection of contrast in the presence of LAD stenosis and the hypoperfused myocardium as determined by radiolabeled microspheres ( y =0.8 x +4.2, r =.90, P <.001, SEE=2.4, n=11). The anterior myocardium was opacified in 6 dogs receiving RA injections of contrast, and the hypoperfused area during LAD stenosis correlated closely with that determined by radiolabeled microspheres ( y =0.86 x +3.4, r =.93, P <.01). Conclusions Coronary stenoses, which are not flow limiting at rest, can be detected and the degree and spatial extent of blood flow mismatch during pharmacologically induced coronary hyperemia can be quantified with MCE using LA and RA injections of contrast. Thus, it is possible that the severity of coronary stenoses and the quantum of myocardium in jeopardy could be quantified in the future with MCE using venous injection of contrast.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 52 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3