Serial Assessment of the Cardiovascular System in Normal Pregnancy

Author:

Poppas Athena1,Shroff Sanjeev G.1,Korcarz Claudia E.1,Hibbard Judith U.1,Berger David S.1,Lindheimer Marshall D.1,Lang Roberto M.1

Affiliation:

1. the Departments of Medicine and Obstetrics and Gynecology and the Committee on Clinical Pharmacology, University of Chicago (Ill) Medical Center.

Abstract

Background Temporal changes in systemic arterial compliance and wave propagation properties (pulsatile arterial load) and their role in ventricular–systemic arterial coupling during gestation have not been explored. Noninvasive methods combined with recently developed mathematical modeling techniques were used to characterize vascular and left ventricular (LV) mechanical adaptations during normal gestation. Methods and Results Fourteen healthy women were studied at each trimester of pregnancy and again postpartum. Experimental measurements included instantaneous aortic pressure (subclavian pulse tracings) and flow (aortic Doppler velocities) and echocardiographic imaging of the LV. A small increase in LV muscle mass and end-diastolic chamber dimension occurred by late gestation, with no significant alterations in myocardial contractility. Cardiac output increased and the steady component of arterial load (total vascular resistance) decreased during pregnancy. Several changes in pulsatile arterial load were noted: Global arterial compliance increased (≈30%) during the first trimester and remained elevated thereafter. The magnitude of peripheral wave reflections at the aorta was reduced. The mathematical model-based analysis revealed that peripheral wave reflections at the aorta were delayed and that both conduit and peripheral vessels contributed to the increased arterial compliance. Finally, coordinated changes in the pulsatile arterial load and LV properties were responsible for maintaining the efficiency of LV-to–arterial system energy transfer. Conclusions The rapid time course of compliance changes and the involvement of both conduit and peripheral vessels are consistent with reduced vascular tone as being the main underlying mechanism. The pulsatile arterial load alterations during normal pregnancy are adaptive in that they help to accommodate the increased intravascular volume while maintaining the efficiency of ventricular-arterial coupling and diastolic perfusion pressure.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 288 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3