Endocardial Carbon-Braid Electrodes

Author:

Alt Eckhard U.1,Fotuhi Parwis C.1,Callihan Richard L.1,Mestre Edgar1,Smith William M.1,Ideker Raymond E.1

Affiliation:

1. From the I. Medizinische Klinik, Technische Universität München, Germany (E.U.A., P.C.F., E.M.); the Departments of Medicine and Pathology, Duke University Medical Center, Durham, NC; the Engineering Research Center for Emerging Cardiovascular Technologies and the Department of Biomedical Engineering of the School of Engineering, Duke University, Durham, NC.

Abstract

Background In the treatment of patients with life-threatening ventricular arrhythmia, transvenous implantable cardioverter/defibrillators provide significant advantages over devices requiring a thoracotomy. This study tested the hypothesis that a new carbon-fiber electrode, designed at the Technische Universität in Munich, Germany, has a lower defibrillation threshold (DFT) than standard transvenous defibrillation electrodes. Methods and Results In 8 mongrel dogs (weight, 25.2±0.8 kg; heart weight, 192±19 g), we examined the efficacy and electrical characteristics of a right ventricular endocardial carbon prototype defibrillation electrode (9.5F, 4.4-cm 2 surface) compared with a standard CPI 0062 Endotak electrode and a Medtronic 6966 Transvene endocardial right ventricular defibrillation electrode. The new electrode consists of 24 braided, tubular carbon filaments, each containing 1000 highly isotropic carbon fibers of 7-μm diameter, yielding a theoretical electrical surface of 480 cm 2 . The DFTs were determined in random order between each of the three right ventricular electrodes and a subcutaneous wire array anode placed on the left thorax. A standard step-down/-up DFT protocol of 20-V shock steps was applied. Two different biphasic waveforms with a 1-ms delay between phases were tested: 3.2-ms first phase/2.0-ms second phase, and 6.0-ms first phase/6.0-ms second phase. For the 3.2/2.0-ms waveform, we found a significantly lower DFT for the carbon lead (4.96±1.58 J) compared with the CPI 0062 (6.93±1.67 J) and the Medtronic 6966 (7.49±0.99 J) leads. For the 6.0/6.0-ms waveform, the DFT for the carbon electrode (5.97±2.09 J) was significantly lower than for the Medtronic 6966 lead (8.55±1.93 J) but not for the CPI 0062 lead (6.30±1.41 J). The impedance with carbon was lower than with the other two leads for the 6.0/6.0-ms waveform but not for the 3.2/2.0-ms waveform. For the carbon electrode, the 3.2/2.0-ms waveform had a lower DFT than the 6.0/6.0-ms waveform. Conclusions The present canine study found a lower DFT for a new carbon electrode compared with DFTs for endocardial defibrillation electrodes made of standard metal. Further long-term animal studies and clinical studies are needed to determine whether carbon materials and braided-lead technology are practical and beneficial in patients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Manufacturing processes for braided composite materials;Handbook of Advances in Braided Composite Materials;2024

2. Manufacturing processes for braided composite materials;Handbook of Advances in Braided Composite Materials;2017

3. Recent advances in 3D braiding technology;Advances in 3D Textiles;2015

4. The Implantable Cardioverter-Defibrillator Lead: Principles, Progress, and Promises;Pacing and Clinical Electrophysiology;2009-10

5. Capture of Atrial Fibrillation Reduces the Atrial Defibrillation Threshold;Pacing and Clinical Electrophysiology;2002-08

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3