Virtual Electrode–Induced Phase Singularity

Author:

Efimov Igor R.1,Cheng Yuanna1,Van Wagoner David R.1,Mazgalev Todor1,Tchou Patrick J.1

Affiliation:

1. From the Department of Cardiology, Cleveland Clinic Foundation, Cleveland, Ohio.

Abstract

Abstract —Delivery of a strong electric shock to the heart remains the only effective therapy against ventricular fibrillation. Despite significant improvements in implantable cardioverter defibrillator (ICD) therapy, the fundamental mechanisms of defibrillation remain poorly understood. We have recently demonstrated that a monophasic defibrillation shock produces a highly nonuniform epicardial polarization pattern, referred to as a virtual electrode pattern (VEP). The VEP consists of large adjacent areas of strong positive and negative polarization. We sought to determine whether the VEP may be responsible for defibrillation failure by creating dispersion of postshock repolarization and reentry. Truncated exponential biphasic and monophasic shocks were delivered from a bipolar ICD lead in Langendorff-perfused rabbit hearts. Epicardial electrical activity was mapped during and after defibrillation shocks and shocks applied at the plateau phase of a normal action potential produced by ventricular pacing. A high-resolution fluorescence mapping system with 256 recording sites and a voltage-sensitive dye were used. Biphasic shocks with a weak second phase (<20% leading-edge voltage of the second phase with respect to the leading-edge voltage of the first phase) produced VEPs similar to monophasic shocks. Biphasic shocks with a strong second phase (>70%) produced VEPs of reversed polarity. Both of these waveforms resulted in extra beats and arrhythmias. However, biphasic waveforms with intermediate second-phase voltages (20% to 70% of first-phase voltage) produced no VEP, because of an asymmetric reversal of the first-phase polarization. Therefore, there was no substrate for postshock dispersion of repolarization. Shocks producing strong VEPs resulted in postshock reentrant arrhythmias via a mechanism of phase singularity. Points of phase singularity were created by the shock in the intersection of areas of positive, negative, and no polarization, which were set by the shock to excited, excitable, and refractory states, respectively. Shock-induced VEPs may reinduce arrhythmias via a phase-singularity mechanism. Strong shocks may overcome the preshock electrical activity and create phase singularities, regardless of the preshock phase distribution. Optimal defibrillation waveforms did not produce VEPs because of an asymmetric effect of phase reversal on membrane polarization.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Reference33 articles.

1. Prevost JL Battelli F. Sur quelques effets des décharges électriques sur le coeur des mammifères. Comptes Rendus Séances Acad Sci. 1899;129:1267.

2. VENTRICULAR FIBRILLATION OF LONG DURATION ABOLISHED BY ELECTRIC SHOCK

3. Termination of Ventricular Fibrillation in Man by Externally Applied Electric Countershock

4. Standby Automatic Defibrillator

Cited by 213 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献