Spectral Analysis of Blood Pressure Variability in Heart Transplant Patients

Author:

Hughson Richard L.1,Maillet Alain1,Dureau Georges1,Yamamoto Yoshiharu1,Gharib Claude1

Affiliation:

1. From the Laboratoire de Physiologie de l’Environnement, Faculté de Médecine Grange-Blanche, Université Claude Bernard, Lyon; INSERM Hôpital Cardiovasculaire, Bron, France; and Department of Kinesiology, Faculty of Applied Health Sciences, University of Waterloo (Ontario, Canada).

Abstract

Abstract The cardiac transplant patient provides a unique model for the study of blood pressure variability in the absence of heart rate variability. We examined the harmonic and fractal components of blood pressure variability in 14 heart transplant patients (12 men, 2 women; 21 to 62 years of age) and in age- and sex-matched control subjects during seated rest, supine rest, and supine rest with fixed-pace breathing (12 respirations per minute). Heart rate was faster in transplant patients than in control subjects, with much less heart rate variability ( P <.0001). Spectral analysis of blood pressure variability revealed no difference in total power for either systolic or diastolic pressure, but transplant patients had less low-frequency (0 to 0.15 Hz) harmonic spectral power in both systolic ( P <.01) and diastolic ( P <.03) pressure and more high-frequency power (0.15 to 0.5 Hz) in diastolic pressure than control subjects. The ratio of high-frequency power in diastolic relative to systolic pressure was consistently higher ( P <.0001) in the transplant patients (0.29 to 0.51) than in control subjects (0.11 to 0.13). The slope of the fractal component of systolic pressure was approximately 1.8 in both transplant patients and control subjects. This was greater than the slope for heart rate variability (approximately 1.1 in control subjects). These data provide clear evidence of independence of the fractal component of heart rate and blood pressure variabilities in both transplant patients and control subjects. The heart rate component of the arterial baroreflex minimized high-frequency diastolic pressure changes while contributing to low-frequency variations in both systolic and diastolic pressures.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

Cited by 30 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3