Twenty-Four–Hour Noninvasive Blood Pressure Monitoring and Pain Perception

Author:

Guasti Luigina1,Cattaneo Rossana1,Rinaldi Orlando1,Rossi Maria Grazia1,Bianchi Lorenzo1,Gaudio Giovanni1,Grandi Anna Maria1,Gorini Giovanna1,Venco Achille1

Affiliation:

1. From the Cattedra di Medicina Interna, II Facoltà di Medicina e Chirurgia, Università degli Studi di Pavia, Sede Varese, e Servizio di Fisica Sanitaria (L.B.), Ospedale Multizonale, Varese, Italy.

Abstract

Abstract Although a hypertension-related hypalgesia has been described, the relation between pain perception and the 24-hour blood pressure trend is still unknown. The ambulatory blood pressure monitoring parameters and dental pain sensitivity were correlated in 67 male subjects. The pulpar test (graded increase of test current of 0 to 0.03 mA) was performed on three healthy teeth, and mean dental pain threshold (occurrence of pulp sensation) and pain tolerance (time when the subjects asked for the test to be stopped) were evaluated. Three groups of subjects with normal (n=34), intermediate (n=13), and high (n=20) blood pressure values were identified according to ambulatory monitoring results. Pain threshold differed among the three groups ( P <.02), being higher in the group with highest blood pressure. The groups of hypertensive subjects showed higher pain tolerance than the normotensive group ( P <.02). Pain threshold was correlated with 24-hour, diurnal, and nocturnal blood pressure values. Pain tolerance was also related to 24-hour blood pressure and to diurnal and nocturnal diastolic and mean arterial pressure values. Systolic and diastolic blood pressure loads were significantly associated with pain threshold, and diastolic load was also associated with tolerance. The blood pressure variability (SD) did not relate to pain perception. The 24-hour arterial pressure was more closely associated with pain perception than the blood pressure values obtained before the pulpar test. A close correlation between pain perception and 24-hour ambulatory blood pressure was demonstrated. The 24-hour mean blood pressure and loads, more than dynamic variations, were related to pain sensitivity, suggesting that the cardiovascular modulation of pain perception may be influenced mainly by sustained levels of arterial pressure.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

Cited by 63 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3