Baroreflex Sensitivity Assessed by Complex Demodulation of Cardiovascular Variability

Author:

Kim Shin Y.1,Euler David E.1

Affiliation:

1. From the Departments of Thoracic and Cardiovascular Surgery (S.Y.K.) and Medicine (D.E.E.), Loyola University Medical Center, Maywood, Ill.

Abstract

Abstract We used complex demodulation of cardiac interval and systolic arterial blood pressure oscillations in the low-frequency band (0.04 to 0.14 Hz) to investigate baroreceptor control of heart rate. Baroreflex sensitivity was defined as the instantaneous amplitude of complex-demodulated oscillations in the RR interval divided by the instantaneous amplitude of complex-demodulated oscillations in systolic blood pressure. We evaluated the method using both simulated and actual data obtained from 33 healthy nonsmokers during supine and standing postures. To test the validity and reliability of the method, we compared the mean values of baroreflex sensitivity calculated using complex demodulation with the values obtained using power spectral analysis and sequential analysis of spontaneous variations in blood pressure and RR interval. All three methods applied to the simulated data yielded the same values of baroreceptor sensitivity. Mean values of baroreflex sensitivity assessed by complex demodulation of the actual data were similar to those calculated by both power spectral analysis and sequential analysis (13.9±5.2 versus 13.7±6.7 or 14.3±6.5 ms/mm Hg for supine and 7.3±2.8 versus 7.0±3.0 or 7.2±2.8 ms/mm Hg for standing, respectively). In addition, a significant correlation existed between the values obtained by complex demodulation and power spectral analysis ( r =.97, P =.0001) and sequential analysis ( r =.98, P =.0001). Furthermore, complex demodulation–derived baroreflex sensitivity fluctuated across time during both the supine and standing postures, and this could not be discerned by power spectral analysis. The results indicate that complex demodulation provides a dynamic assessment of baroreflex sensitivity and may be a useful tool in exploring reflex autonomic control of the cardiovascular system.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

Cited by 24 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3