Detection of Coronary Artery Stenosis With Power Doppler Imaging

Author:

Villanueva Flordeliza S.1,Gertz Edward W.1,Csikari Melissa1,Pulido Gregory1,Fisher David1,Sklenar Jiri1

Affiliation:

1. From the University of Pittsburgh School of Medicine (F.S.V., M.C., D.F.), Cardiovascular Institute, Pittsburgh, Pa; POINT Biomedical (E.W.G., G.P.), San Carlos, Calif; and the University of Virginia (J.S.), Charlottesville, Va.

Abstract

Background —Power Doppler is a new imaging method for detecting microbubbles during myocardial contrast echocardiography (MCE) based on the registration of variance resulting from ultrasound-induced nonlinear bubble behavior. We tested the hypothesis that power Doppler imaging can be used to quantify coronary stenoses. Methods and Results —Three left anterior descending (LAD) coronary stenoses of varying severity were created in each of 9 open-chest dogs. MCE was performed by continuous intravenous infusion of a nitrogen-filled bilayer shell microbubble, PB127, during triggered power Doppler imaging at incremental pulsing intervals. MCE and radiolabeled microsphere measurements were made at baseline and during each stenosis, with and without adenosine stress. Videointensities in the LAD and left circumflex (LCx) beds were plotted against pulsing interval and fit to a previously described exponential function modeling microbubble destruction and replenishment, which was used to derive parameters of bubble velocity (β) and peak plateau videointensity (A). Contrast defects matching the location of radiolabeled microsphere hypoperfusion were clearly seen, without need for image processing. The product of β and A was linearly related to LAD/LCx flow ( r =0.90, P <0.0001) and inversely related to stenosis gradient ( r =−0.70, P <0.0001). Endocardial/epicardial flow ratios were visualized and quantifiable. Conclusions —As with B-mode harmonics, a model of microbubble destruction/replenishment can be applied to power Doppler data as a means to detect a broad range of stenoses. Image clarity and the lack of attenuation or requirement for background subtraction are additional advantages of this imaging approach. Power Doppler MCE imaging holds promise for the detection of coronary artery disease.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 33 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3