Visualization and Temporal/Spatial Characterization of Cardiac Radiofrequency Ablation Lesions Using Magnetic Resonance Imaging

Author:

Lardo Albert C.1,McVeigh Elliot R.1,Jumrussirikul Pitayadet1,Berger Ronald D.1,Calkins Hugh1,Lima João1,Halperin Henry R.1

Affiliation:

1. From the Departments of Radiology (A.C.L., E.R.M.), Medicine (A.C.L., P.J., R.D.B., H.C., J.L., H.R.H.), Biomedical Engineering (A.C.L., E.R.M., H.R.H.), and Surgery (A.C.L.), Johns Hopkins University School of Medicine, Baltimore, Md.

Abstract

Background —The purpose of this study was to describe a system and method for creating, visualizing, and monitoring cardiac radiofrequency ablation (RFA) therapy during magnetic resonance imaging (MRI). Methods and Results —RFA was performed in the right ventricular apex of 6 healthy mongrel dogs with a custom 7F nonmagnetic ablation catheter (4-mm electrode) in a newly developed real-time interactive cardiac MRI system. Catheters were positioned to intracardiac targets by use of an MRI fluoroscopy sequence, and ablated tissue was imaged with T2-weighted fast spin-echo and contrast-enhanced T1-weighted gradient-echo sequences. Lesion size by MRI was determined and compared with measurements at gross and histopathological examination. Ablated areas of myocardium appeared as hyperintense regions directly adjacent to the catheter tip and could be detected 2 minutes after RF delivery. Lesions reached maximum size ≈5 minutes after ablation, whereas lesion signal intensity increased linearly with time but then reached a plateau at 12.2±2.1 minutes. Lesion size by MR correlated well with actual postmortem lesion size and histological necrosis area (55.4±7.2 versus 49.7±5.9 mm 2 , r =0.958, P <0.05). Conclusions —RFA can be performed in vivo in a new real-time interactive cardiac MRI system. The spatial and temporal extent of cardiac lesions can be visualized and monitored by T2- and T1-weighted imaging, and MRI lesion size agrees well with actual postmortem lesion size. MRI-guided RFA may be a useful approach to help facilitate anatomic lesion placement and to provide insight into the biophysical effects of new ablation techniques and technologies.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 194 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3