Affiliation:
1. Aero Medical Laboratory, Wright Air Development Center Wright Patterson Air Force Base, O
Abstract
Changes in central venous pressure were recorded continuously before, during and for 40 to 50 minutes after hemorrhage and transfusion in the amounts of 6.5 cc. per Kg. and 8.1 cc. per Kg. The pressures obtained 15 to 20 minutes after onset of blood volume changes were independent of the rate of hemorrhage or transfusion. In the average subject of 70 Kg., Δ
P
/ΔV for zero time was 0.7 cm. of water pressure change per 100 cc. volume change. Recovery from hemorrhage was imperceptible during the one hour observation period, but recovery from transfusion was slightly faster.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Cardiology and Cardiovascular Medicine,Physiology
Cited by
118 articles.
订阅此论文施引文献