Amyloid Transthyretin Cardiomyopathy in Elderly Patients With Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation

Author:

Dobner Stephan1ORCID,Pilgrim Thomas1ORCID,Hagemeyer Daniel1ORCID,Heg Dik2ORCID,Lanz Jonas1ORCID,Reusser Nicole1,Gräni Christoph1ORCID,Afshar‐Oromieh Ali3,Rominger Axel3ORCID,Langhammer Bettina4,Reineke David4,Windecker Stephan1ORCID,Stortecky Stefan1ORCID

Affiliation:

1. Department of Cardiology, Inselspital Bern University Hospital, University of Bern Bern Switzerland

2. CTU Bern University of Bern Bern Switzerland

3. Department of Nuclear Medicine, Inselspital Bern University Hospital, University of Bern Bern Switzerland

4. Department of Cardiovascular Surgery, Inselspital University of Bern Bern Switzerland

Abstract

Background The prevalence of calcific aortic stenosis and amyloid transthyretin cardiomyopathy (ATTR‐CM) increase with age, and they often coexist. The objective was to determine the prevalence of ATTR‐CM in patients with severe aortic stenosis and evaluate differences in presentations and outcomes of patients with concomitant ATTR‐CM undergoing transcatheter aortic valve implantation. Methods and Results Prospective screening for ATTR‐CM with Technetium 99 ‐3,3‐diphosphono‐1,2‐propanodicarboxylic acid bone scintigraphy was performed in 315 patients referred with severe aortic stenosis between August 2019 and August 2021. Myocardial Technetium 99 ‐3,3‐diphosphono‐1,2‐propanodicarboxylic acid tracer uptake was detected in 34 patients (10.8%), leading to a diagnosis of ATTR‐CM in 30 patients (Perugini ≥2: 9.5%). Age (85.7±4.9 versus 82.8±4.5; P =0.001), male sex (82.4% versus 57.7%; P =0.005), and prior carpal tunnel surgery (17.6% versus 4.3%; P =0.007) were associated with coexisting ATTR‐CM, as were ECG (discordant QRS voltage to left ventricular wall thickness [42% versus 12%; P <0.001]), echocardiographic (left ventricular ejection fraction 48.8±12.8 versus 58.4±10.8; P <0.001; left ventricular mass index, 144.4±45.8 versus 117.2±34.4g/m 2 ; P <0.001), and hemodynamic parameters (mean aortic valve gradient, 23.4±12.6 versus 35.5±16.6; P <0.001; mean pulmonary artery pressure, 29.5±9.7 versus 25.8±9.5; P =0.037). Periprocedural (cardiovascular death: hazard ratio [HR], 0.71 [95% CI, 0.04–12.53]; stroke: HR, 0.46 [95% CI, 0.03–7.77]; pacemaker implantation: HR, 1.54 [95% CI, 0.69–3.43]) and 1‐year clinical outcomes (cardiovascular death: HR, 1.04 [95% CI, 0.37–2.96]; stroke: HR, 0.34 [95% CI, 0.02–5.63]; pacemaker implantation: HR, 1.50 [95% CI, 0.67–3.34]) were similar between groups. Conclusions Coexisting ATTR‐CM was observed in every 10th elderly patient with severe aortic stenosis referred for therapy. While patients with coexisting pathologies differ in clinical presentation and echocardiographic and hemodynamic parameters, peri‐interventional risk and early clinical outcomes were comparable up to 1 year after transcatheter aortic valve implantation. REGISTRATION URL: https://www.clinicaltrials.gov . Unique identifier: NCT04061213.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3