Pharmacological mechanisms for left ventricular unloading in clinical congestive heart failure. Differential effects of nitroprusside, phentolamine, and nitroglycerin on cardiac function and peripheral circulation.

Author:

Miller R R,Vismara L A,Williams D O,Amsterdam E A,Mason D T

Abstract

We compared cardiocirculatory actions of the commonly employed systemic vasodilators, intravenous (iv) nitroprusside (NP), iv phentolamine (PH), and sublingual nitroglycerin (NTG), causing left ventricular (LV) unloading in 29 chronic coronary subjects with congestive failure to determine whether they produce disparate responses in LV function by different relaxing actions on systemic resistance and capacitance beds. Each drug equally lowered systemic arterial pressures to a small extent, whereas heart rate rose slightly with NTG. Cardiac catheterization showed a decline in end-diastolic pressure with NTG (19 to 8 mm Hg) which was greater (P less than 0.05) than with NP and PH (21 to 11). Cardiac index increased (P less than 0.05) during NP (2.68 to 2.93 liters/min per m2) and PH (2.60 to 3.02) but was unchanged (2.83) by NTG. Stroke work increased with PH, ejection fraction rose with NP and PH, and mean ejection rate increased with each, whereas pressure-time per minute fell and end-diastolic volume decreased with each agent. Total systemic vascular resistance declined (P less than 0.001) during NP and PH (1,475 to 1,200 dynes sec cm-5) but was unchanged (1,487) by NTG. Plethysmographically, forearm vascular resistance (FVR) decreased (P less than 0.01) with NP and PH (61.6 to 39.1 mm Hg/ml per 100 g/min) but not (52.4) by NTG. The decreases in venous tone (VT) with NTG (18.2 to 9.3 mm Hg/ml) and NP (18.5 to 9.8) were greater (P less than 0.05) than with PH (18.8 to 13.1) FVR/VT percent changes of 0.96, 1.62, and 0.53 with NP, PH, and NTG indicated balanced systemic arteriolovenous relaxation by iv NP, greater arteriolar dilation with iv PH, and predominant venous dilation by sublingual NTG. Thus, vasodilators produce disparate modifications of LV function by their differing alterations of preload and impedance, which are dependent upon relative extents of relaxation of systemic resistance and capacitance vessels characteristic of each agent as used clinically.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Cited by 296 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3