Abstract

Background In‐stent hyperplasia ( ISH ) may develop in regions of low endothelial shear stress ( ESS ), but the relationship between the magnitude of low ESS , the extent of ISH, and subsequent clinical events has not been investigated. Methods and Results We assessed the association of poststent ESS with neointimal ISH and clinical outcomes in patients treated with percutaneous coronary interventions ( PCI ). Three‐dimensional coronary reconstruction was performed in 374 post‐ PCI patients at baseline and 6 to 10 months follow‐up as part of the PREDICTION Study. Each vessel was divided into 1.5‐mm‐long segments, and we calculated the local ESS within each stented segment at baseline. At follow‐up, we assessed ISH and the occurrence of a clinically indicated repeat PCI for in‐stent restenosis. In 246 total stents (54 overlapping), 100 (40.7%) were bare‐metal stents ( BMS ), 104 (42.3%) sirolimus‐eluting stents, and 42 (17.1%) paclitaxel‐eluting stents. In BMS , low ESS post‐ PCI at baseline was independently associated with ISH (β=1.47 mm 2 per 1‐Pa decrease; 95% CI , 0.38–2.56; P <0.01). ISH was minimal in drug‐eluting stents. During follow‐up, repeat PCI in BMS was performed in 21 stents (8.5%). There was no significant association between post‐ PCI ESS and in‐stent restenosis requiring PCI . Conclusions Low ESS after BMS implantation is associated with subsequent ISH . ISH is strongly inhibited by drug‐eluting stents. Post‐ PCI ESS is not associated with in‐stent restenosis requiring repeat PCI . ESS is an important determinant of ISH in BMS , but ISH of large magnitude to require PCI for in‐stent restenosis is likely attributed to factors other than ESS within the stent.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3