Diffusion-Weighted Imaging and Fluid-Attenuated Inversion Recovery Quantification to Predict Diffusion-Weighted Imaging-Fluid-Attenuated Inversion Recovery Mismatch Status in Ischemic Stroke With Unknown Onset

Author:

Scheldeman Lauranne123ORCID,Wouters Anke1234ORCID,Dupont Patrick56ORCID,Christensen Søren7,Boutitie Florent89,Cheng Bastian10ORCID,Ebinger Martin1112,Endres Matthias1113141516ORCID,Fiebach Jochen B.11ORCID,Gerloff Christian10ORCID,Muir Keith W.17ORCID,Nighoghossian Norbert1819ORCID,Pedraza Salvador20ORCID,Simonsen Claus Z.21ORCID,Thijs Vincent2223ORCID,Thomalla Götz10ORCID,Lemmens Robin123ORCID

Affiliation:

1. Department of Neurology, University Hospitals Leuven, Belgium (L.S., A.W., R.L.).

2. Department of Neurosciences, Experimental Neurology (L.S., A.W., R.L.), KU Leuven – University of Leuven, Belgium.

3. Center for Brain and Disease Research, Laboratory of Neurobiology, VIB, Leuven, Belgium (L.S., A.W., R.L.).

4. Neurology, Amsterdam University Medical Centers, the Netherlands (A.W.).

5. Department of Neurosciences, Laboratory for Cognitive Neurology (P.D.), KU Leuven – University of Leuven, Belgium.

6. Leuven Brain Institute, Belgium (P.D.).

7. GrayNumber Analytics, Lomma, Sweden (S.C.).

8. Hospices Civils de Lyon, Service de Biostatistique, France (F.B.).

9. Université Lyon 1, Villeurbanne, France (F.B.).

10. Klinik und Poliklinik für Neurologie, Kopf- und Neurozentrum, University Medical Center Hamburg-Eppendorf, Germany (B.C., C.G., G.T.).

11. Center for Stroke Research Berlin (CSB) (M. Ebinger, M. Endres, J.B.F.), Charité – Universitätsmedizin Berlin, Germany.

12. Klinik für Neurologie, Medical Park Berlin Humboldtmühle, Germany (M. Ebinger).

13. Klinik und Hochschulambulanz für Neurologie (M. Endres), Charité – Universitätsmedizin Berlin, Germany.

14. German Center for Cardiovascular Research (DZHK), partner site Berlin (M. Endres).

15. German Center for Neurodegenerative Diseases (DZNE), partner site Berlin (M. Endres).

16. ExcellenceCluster NeuroCure (M. Endres).

17. Institute of Neuroscience and Psychology, University of Glasgow, United Kingdom (K.W.M.).

18. Department of Stroke Medicine, Université Claude Bernard Lyon 1, CREATIS CNRS UMR 5220-INSERM U1206, INSA- Lyon (N.N.).

19. Hospices Civils de Lyon, France (N.N.).

20. Department of Radiology, Institut de Diagnostic per la Image (IDI), Hospital Dr Josep Trueta, Institut d’Investigació Biomedica de Girona (IDIBGI), Parc Hospitalari Marti i Julia de Salt – Edifici M2, Girona, Spain (S.P.).

21. Department of Neurology, Aarhus University Hospital, Denmark (C.Z.S.).

22. Stroke Theme, Florey Institute of Neuroscience and Mental Health, University of Melbourne, Heidelberg, Victoria, Australia (V.T.).

23. Department of Neurology, Austin Health, Heidelberg, Victoria, Australia (V.T.).

Abstract

Background: Visual rating of diffusion-weighted imaging (DWI)–fluid-attenuated inversion recovery (FLAIR) mismatch can be challenging. We evaluated quantification of DWI and FLAIR to predict DWI-FLAIR mismatch status in ischemic stroke. Methods: In screened patients from the WAKE-UP trial (Efficacy and Safety of Magnetic Resonance Imaging-Based Thrombolysis in Wake-Up Stroke), we retrospectively studied relative DWI (rDWI SI) and FLAIR signal intensity (rFLAIR SI). We defined the optimal mean rFLAIR SI and interquartile range of the rDWI SI in the DWI lesion to predict DWI-FLAIR mismatch status. We investigated agreement between each quantitative parameter and the DWI-FLAIR mismatch and the association between both quantitative parameters. We evaluated the predictive value of the quantitative parameters for excellent functional outcome by logistic regression, adjusted for DWI lesion volume, treatment, age, and National Institutes of Health Stroke Scale score. Results: In the rFLAIR and rDWI SI analysis, 213/369 and 241/421 subjects respectively had a DWI-FLAIR mismatch. A mean rFLAIR SI cutoff of 1.09 and interquartile range rDWI SI cutoff of 0.47 were optimal to predict the DWI-FLAIR mismatch with a sensitivity and specificity of 77% (95% CI, 71%–83%) and 67% (95% CI, 59%–74%), and 76% (95% CI, 70%–81%) and 72% (95% CI, 65%–79%), respectively. For both quantitative parameters, agreement with the DWI-FLAIR mismatch was fair (73%, κ=0.44 [95% CI, 0.35–0.54] for rFLAIR and 74%, κ=0.48 [95% CI, 0.39–0.56] for rDWI). Both quantitative parameters correlated moderately (Pearson R=0.54 [95% CI, 0.46–0.61]; P <0.001, n=367). The interquartile range rDWI SI (n=188), but not the mean rFLAIR SI (n=172), was an independent predictor of excellent functional outcome (odds ratio, 0.67 per 0.1 unit increase of interquartile range rDWI SI, 95% CI, 0.51–0.89, P =0.01). Conclusions: Agreement between the quantitative and qualitative approach may be insufficient to advocate DWI or FLAIR quantification as alternative for visual rating.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3