US Wingspan Registry

Author:

Fiorella David J.1,Turk Aquilla S.1,Levy Elad I.1,Pride G. Lee1,Woo Henry H.1,Albuquerque Felipe C.1,Welch Babu G.1,Niemann David B.1,Aagaard-Kienitz Beverly1,Rasmussen Peter A.1,Hopkins L. Nelson1,Masaryk Thomas J.1,McDougall Cameron G.1

Affiliation:

1. From the Cerebrovascular Center (D.J.F., H.H.W.), Department of Neurosurgery, State University of New York at Stony Brook, Stony Brook, NY; the Departments of Neuroradiology and Neurosurgery (A.S.T.), Medical University of South Carolina, Charleston, SC; the Departments of Neurosurgery and Radiology (E.I.L., L.N.H.), University at Buffalo, State University of New York, Buffalo, NY; the Departments of Neurosurgery and Neuroradiology (G.L.P., B.G.W.), University of Texas Southwestern, Dallas, TX; the...

Abstract

Background and Purpose— The purpose of this study is to present 12-month follow-up results for a series of patients undergoing percutaneous transluminal angioplasty and stenting with the Gateway-Wingspan stenting system (Boston Scientific) for the treatment of symptomatic intracranial atherostenosis. Methods— Clinical and angiographic follow-up results were recorded for patients from 5 participating institutions. Primary end points were stroke or death within 30 days of the stenting procedure or ipsilateral stroke after 30 days. Results— During a 21-month study period, 158 patients with 168 intracranial atherostenotic lesions (50% to 99%) were treated with the Gateway-Wingspan system. The average follow-up duration was 14.2 months with 143 patients having at least 3 months of clinical follow-up and 110 having at least 12 months. The cumulative rate of the primary end point was 15.7% for all patients and 13.9% for patients with high-grade (70% to 99%) stenosis. Of 13 ipsilateral strokes occurring after 30 days, 3 resulted in death. Of these strokes, 76.9% (10 of 13) occurred within the first 6 months of the stenting procedure and no events were recorded after 12 months. An additional 9 patients experienced ipsilateral transient ischemic attack after 30 days. Most postprocedural events (86%) could be attributed to interruption of antiplatelet medications (n=6), in-stent restenosis (n=12), or both (n=1). In 3 patients, the events were of uncertain etiology. Conclusions— After successful Wingspan percutaneous transluminal angioplasty and stenting, some patients continued to experience ipsilateral ischemic events. Most of these ischemic events occurred within 6 months of the procedure and were associated with the interruption of antiplatelet therapy or in-stent restenosis.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3