High Rate of Magnetic Resonance Imaging Stroke Recurrence in Cryptogenic Transient Ischemic Attack and Minor Stroke Patients

Author:

Bal Simerpreet1,Patel Shiel K.1,Almekhlafi Mohammed1,Modi Jayesh1,Demchuk Andrew M.1,Coutts Shelagh B.1

Affiliation:

1. From the Departments of Clinical Neurosciences (S.B., S.K.P., M.A., A.M.D., S.B.C.), Radiology (J.M., A.M.D., S.B.C.), Hotchkiss Brain Institute (A.M.D., S.B.C.), University of Calgary, Calgary, Canada; Faculty of Medicine, Department of Neurosciences, Section of Neurology, Department of Internal Medicine, Winnipeg, University of Manitoba, Manitoba, Canada (S.B.); King Abdulaziz University, Jeddah, Saudi Arabia (M.A.).

Abstract

Background and Purpose— Cryptogenic stroke is common in patients with transient ischemic attack (TIA) and minor stroke. It is likely that the imaging recurrence risk is higher than the clinical recurrence rate. We sought to determine the rate of clinical and radiographic stroke recurrence in a population of cryptogenic TIA and minor stroke. Methods— Patients with TIA/minor stroke (National Institutes of Health Stroke Scale score ≤3) were prospectively enrolled and imaged within 24 hours of symptom onset as part of 2 cohorts. Patients were assessed at 3 months to document any clinical recurrence and underwent repeat magnetic resonance imaging (MRI) at either 30 or 90 days. Stroke mechanism was categorized as cryptogenic after standard etiologic work-up was completed and was negative. Follow-up MRI was assessed for any new lesions in comparison with baseline imaging. Results— Three hundred thirty-three of 693 (48%) patients had cryptogenic stroke. Of these cryptogenic patients, 207 (62%) had follow-up imaging. At 30-day MRI follow-up, 6.6% (5/76) had new lesions (3 in a remote arterial territory). At 90-day MRI follow-up, 14.5% (19/131) had new lesions (9 in a remote arterial territory). Clinical recurrent stroke was seen in 1.2% (4/333) of patients within 90 days. Conclusions— Cryptogenic etiology is common in a TIA/minor stroke population. This population shows a high rate of silent radiographic recurrence, suggesting active disease. Use of MRI as a surrogate marker of disease activity is 1 potential way of assessing efficacy of new treatments in this population with reduced sample size.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3