Visual Perfusion–Diffusion Mismatch Is Equivalent to Quantitative Mismatch

Author:

Luby Marie1,Ku Katherine D.1,Latour Lawrence L.1,Merino José G.1,Hsia Amie W.1,Lynch John K.1,Warach Steven1

Affiliation:

1. From the National Institute of Neurological Disorders and Stroke (M.L., K.D.K., L.L.L., J.G.M., A.W.H., J.K.L., S.W.), Bethesda, MD; Suburban Hospital Stroke Center (J.G.M.), Bethesda, MD; and Washington Hospital Center Stroke Center (A.W.H.), Washington, DC.

Abstract

Background and Purpose— The concept of stroke MRI mismatch based on qualitative evaluation of diffusion-weighted imaging (DWI) and perfusion-weighted imaging (PWI) has been applied in clinical practice for several years. The benefit of MRI in providing pathological evidence of ischemia before thrombolytic treatment has been demonstrated. The purpose of this study is to determine the reliability of the qualitative method and compare it with quantitative mismatch measurement in thrombolytic-treated patients. Methods— Patients (n=70) were selected from the Lesion Evolution of Stroke and Ischemic On Neuroimaging (LESION) database if they: (1) were treated with intravenous recombinant tissue plasminogen activator; (2) had a pretreatment MRI with evaluable DWI and PWI; and (3) had acute ischemic lesion volume >10 mL on DWI as determined by core imaging laboratory measurements. Quantitative mismatch was defined as a difference of >50 mL between abnormal mean transit time and DWI volumes. Sample characteristics and postdischarge modified Rankin Scale for the positive mismatch patients were compared between the subgroups identified by qualitative versus quantitative methods. Results— Patient characteristics and thrombolytic outcomes (sex, age, National Institutes of Health Stroke Scale, mismatch volume, and modified Rankin Scale) did not differ for mismatch patients identified by qualitative versus quantitative methods. Qualitative mismatch selection among neurologists had a high sensitivity (0.82), specificity (0.80), accuracy (0.81), and positive predictive value (0.88) compared with quantitative measurements. Conclusions— We observed that qualitative evaluation of mismatch identified the same thrombolytic-treated patients compared with retrospective quantitative mismatch measurements.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3