Abstract 9781: Electromechanical Optical Mapping in Beating, in Situ Swine Hearts

Author:

Zhang Hanyu1,Patton Haley N2,Wood Garrett A2,Walcott Greg P1,Rogers Jack M1

Affiliation:

1. Univ of Alabama at Birmingham, Birmingham, AL

2. Biomedical Engineering, Univ of Alabama at Birmingham, Birmingham, AL

Abstract

Introduction: Optical mapping is a powerful method for imaging cardiac propagation but is traditionally limited to motion-arrested, ex vivo preparations. Extending the method to beating, in situ preparations will enable study of bidirectional electromechanical interactions and physiological coupling between the heart and the animal. Challenges in adapting optical mapping to this setting include motion artifact, loading of voltage sensitive dye (VSD), and absorption of excitation and emission light by blood. Here, we outline a system to simultaneously image electrical propagation and contraction of intact beating hearts in an in vivo swine model. Methods: Fifteen pigs weighting 25-35 kg were anesthetized. Hearts were exposed via median sternotomy. We glued 20-30 fiducial markers (2 mm, ~1 cm spacing) to the anterior LV epicardium. We injected 14 ml of 50 uM di-4-ANEQ(F)PTEA into a catheter placed in the LAD. Blood flow in the artery was blocked during and for 1 min following the injection. This VSD works at longer wavelengths than commonly used VSDs and is therefore less affected by blood. Fluorescence was excited with alternating amber (602 nm) and green (526 nm) LEDs. Emission was long pass filtered (>700 nm) and recorded at 750 Hz with a pair of video cameras (SciMedia MiCAM03-N256) fitted with 35 mm, f/1.4 lenses . We analyzed marker motion to (1) quantify contraction and (2) partially correct motion artifact in membrane potential ( Vm ) signals. We also computed the ratio of green- to amber-elicited fluorescence on alternate frames to further correct motion artifact. Results and Conclusions: The method successfully images Vm and deformation. The figure shows an isochronal activation map of a paced beat (A), bars aligned with systolic principal strain (B), and Vm and shortening strain signals from selected sites (C). The method can be used to investigate coupled electromechanics and arrhythmogenesis in a more physiologically realistic setting than previous techniques.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Di-5-ANEQ(F)PTEA Offers Better Performance than Di-4-ANEQ(F)PTEA for In-Situ Cardiac Optical Mapping*;2023 45th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC);2023-07-24

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3