Background and Purpose Transcranial ultrasound diagnostics are particularly hindered by insufficient ultrasound penetration through the temporal bone. The use of ultrasonic contrast media to enhance the Doppler signal is an important step toward the solution of this problem. In the present study we investigated the tolerability and the diagnostic value of a new intravenous transpulmonary ultrasonic contrast medium, BY963. Methods In two phase I studies, 8 healthy volunteers received a spherosome suspension containing a phospholipid as the active ingredient. The intravenous injection was performed in three doses (2.5, 5, and 10 mL) at four different injection rates (0.25, 0.5, and 1 mL/s and bolus). The duration and degree of the signal enhancement were measured by two transcranial ultrasonic procedures presently used in clinical practice: transcranial Doppler sonography (TCD) and transcranial color-coded sonography (TCCS). The assessment of tolerability was based on chemical laboratory parameters and hemodynamic data (heart rate, blood pressure, electrocardiogram) and on questionnaires relating to general well-being. Results BY963 was tolerated without complications. All 38 administrations of the echo contrast medium produced a marked increase in the TCD signal (>30 dB) in the intracranial basal cerebral arteries. To obtain the optimum time window for diagnostic use, higher doses with slower injection rates are advantageous. The duration of optimal contrasting was 42 to 68 seconds (TCD) and 12 to 132 seconds (TCCS), depending on the method and mode of administration. Bolus injections gave rise to an increased incidence of color artifacts. Conclusions BY963 significantly improves intracranial Doppler imaging while being well tolerated. The signal enhancement lasts long enough for TCCS to display all basal cerebral arteries after just one injection.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Cited by 49 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Grundlagen;Praxisbuch Kontrastmittelsonografie;2022

2. Moderne Sonographie zur Diagnostik des akuten Abdomens;Der Radiologe;2010-02-19

3. Aktuelle Entwicklungen in der vaskulären Sonographie;Der Radiologe;2009-10-28

4. The Wada Test-60th Year Anniversary Update-In Epilepsy Surgery;Textbook of Stereotactic and Functional Neurosurgery;2009

5. Ultraschall-Kontrastmittel für neurovaskuläre Anwendungen;Ultraschall in der Medizin;2008-05-16

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3