Consistency of Doppler Parameters in Predicting Arteriographically Confirmed Carotid Stenosis

Author:

Schwartz Skai W.1,Chambless Lloyd E.1,Baker William H.1,Broderick Joseph P.1,Howard George1

Affiliation:

1. the Department of Epidemiology and Biostatistics, College of Public Health of University of South Florida (Tampa) (S.W.S.); the Department of Biostatistics, University of North Carolina at Chapel Hill (L.E.C.); the Section of Vascular Surgery, Loyola University Medical School, Maywood, Ill (W.H.B.); the Department of Neurology of University of Cincinnati (Ohio) Medical School (J.P.B.); and the Department of Public Health Sciences and Stroke Center, Bowman Gray School of Medicine of Wake Forest...

Abstract

Background and Purpose While internal carotid peak systolic velocity (IPSV) is reportedly the best Doppler parameter for predicting lower grades of carotid artery stenosis, the internal carotid end-diastolic velocity (IEDV) or the ratio of IPSV to common carotid end-diastolic velocity (CEDV) is helpful in increasing prediction of higher grade stenoses. It is important to examine the consistency of these findings across machine and technician. Methods Using data from 10 devices from the Asymptomatic Carotid Atherosclerosis Study, we examined the predictive ability of seven Doppler parameters: IPSV, IEDV, CEDV, common carotid peak systolic velocity (CPSV), and the ratios of IPSV/CEDV, IEDV/CEDV, and IEDV/CEDV. To assess the agreement between Doppler and arteriography in classifying percent stenosis above or below a given criterion, sensitivity, specificity, area under the receiver operating curve, and κ statistics were obtained from logistic models. The single best Doppler parameter for each of two grades of stenosis (60% and 80%) was determined, and its predictive ability was compared with that of IPSV. The usefulness of IEDV or IPSV/CEDV in addition to IPSV to determine higher grade stenosis was examined. Results IPSV was the best predictor in 9 of 10 devices at 60% and in 4 devices at 80% stenosis. When another parameter was better than IPSV, the improvement was minimal. Including IEDV or IPSV/CEDV in addition to IPSV did not notably improve predictive ability. Conclusions IPSV is the single best Doppler parameter for distinguishing severe (>80%) from less severe carotid stenosis. Information from other Doppler parameters in addition to IPSV is unlikely to be helpful.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

Cited by 42 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3