Diameter Dependence of Myogenic Tone of Human Pial Arteries

Author:

Thorin-Trescases Nathalie1,Bartolotta Tracy1,Hyman Neil1,Penar Paul L.1,Walters Carrie L.1,Bevan Rosemary D.1,Bevan John A.1

Affiliation:

1. From the Totman Laboratory for Human Cerebrovascular Reseach, Department of Pharmacology (N.T.-T., T.B., R.D.B., J.A.B.) and the Division of Neurosurgery (N.H., P.L.P.), University of Vermont, Burlington, Vt and Neurological Surgeons (C.L.W.), Phoenix, Ariz.

Abstract

Background and Purpose Responses to changes in intraluminal pressure of isolated human pial arteries (200 to 1200 μm i.d.) obtained from patients undergoing neurosurgery were measured. Methods The vessels were cannulated and pressurized (60 mm Hg); vascular diameter and intraluminal pressure were recorded simultaneously. After spontaneous development of steady state tone, intraluminal pressure was changed to both higher and lower levels in random sequence. Results Human pial arteries exhibited myogenic responses and maintained their diameter over the pressure range of 20 to 100 mm Hg. The level of myogenic tone observed at 30 mm Hg did not vary significantly with artery diameter. In contrast, at 60 and 90 mm Hg, the extent of myogenic tone increased as the diameter decreased (up to 70% to 80% of maximum in 200-μm i.d. arteries). The arteries contracted to KCl 30 mmol/L, norepinephrine 1μmol/L, and vasopressin 0.1μmol/L and relaxed to acetylcholine 3 μmol/L. The extent of these responses did not vary with the diameter of the artery. Arterial distensibility, represented by the slope of the tangent of the passive pressure-diameter curve at lower pressures (5 to 50 mm Hg), increased as arteries became smaller. This is consistent with the possibility that the level of myogenic tone is related to vessel distensibility. Human omental arteries of comparable size did not develop myogenic tone but contracted to KCl and norepinephrine and relaxed to acetylcholine to an extent similar to pial arteries. Conclusions There is a specific gradient of myogenic responsiveness in human pial arteries that varies inversely with their diameter. This tone does not develop in all vascular beds. These levels of tone in the pial circulation would be expected to be of profound functional significance by allowing blood flow to vary widely.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3