Quantification of ultrasound emboli signals in patients with cardiac and carotid disease.

Author:

Grosset D G1,Georgiadis D1,Kelman A W1,Lees K R1

Affiliation:

1. Acute Stroke Unit, Western Infirmary, Glasgow, UK.

Abstract

The use of Doppler ultrasound to detect arterial emboli has major implications for the classification and treatment of stroke. Experimental studies indicate that embolic materials produce different ultrasound signals, depending on their acoustic properties. To examine the possibility of characterizing emboli of different sources in the clinical setting, we compared the emboli signals of patients with cardiac embolic sources with those of patients with signals of carotid embolic sources. Transcranial Doppler monitoring (30 minutes per patient) of the middle cerebral arteries was performed in 80 patients with prosthetic cardiac valves and 20 patients with internal carotid artery stenosis. The signal power of emboli was calculated in relation to the background Doppler signal. In patients who were embolizing from prosthetic heart valves, the frequency of embolus signals was greater than in patients with carotid stenosis who were embolizing (mean +/- SEM: 58.2 +/- 11 versus 8.2 +/- 3 signals per hour; P < .0001, two-sample t test), and total signal power and duration also were higher (power, 2231 +/- 63 versus 455 +/- 109 power units; duration, 55.9 +/- 0.8 versus 29.9 +/- 1.4 milliseconds; both P < .001). The majority of emboli signals were seen during cardiac systole, especially in patients with carotid stenosis (89% in the first half of the cardiac cycle versus 72% in prosthetic valve patients). In 19 patients with prosthetic valves, embolus signals were also recorded from the anterior cerebral artery; the signal count was not significantly different from the middle cerebral artery (43.2 +/- 12.5 versus 64.3 +/- 16 per hour), but anterior cerebral artery signals were of higher power (3306 +/- 148 versus 2441 +/- 109 power units, P < .001). There is promise of being able to distinguish emboli on the basis of power measurements. Emboli of different sources (eg, carotid and cardiac) appear to have different ultrasonic characteristics, which are likely to be based on composition and size.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Cited by 81 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3