Use of a Decibel Threshold in Detecting Doppler Embolic Signals

Author:

Markus Hugh S.1,Molloy Jane1

Affiliation:

1. From the Department of Neurology, King’s College School of Medicine and Dentistry, and the Institute of Psychiatry, London, UK.

Abstract

Background and Purpose To improve reproducibility and reliability in the identification of embolic signals detected with the use of Doppler ultrasound, many studies have used an intensity threshold. However, variable thresholds between 3 and 12 dB have been used, and often the method of measurement of intensity is not stated. Potentially different methods of measurement could result in different intensity measurements for the same embolic signal. We determined the effect of these differences using commercial transcranial Doppler systems. Methods We analyzed 81 embolic signals recorded from the middle cerebral arteries of patients with carotid artery disease using three different methods of measuring intensity that had been previously used in research studies. In method 1 individual time frames of the frequency spectra were analyzed, in method 2 a color-coded intensity scale was used, and in method 3 automated software was used. Results There was a highly significant correlation between measurements made by the different techniques (method 1 versus method 2: r =.68, P <.0001; method 1 versus method 3: r =.66, P <.0001; method 2 versus method 3: r =.70, P <.0001). However, the absolute values of intensity for the same embolic signals varied markedly for the different methods. For example, a 4-dB threshold according to method 1 was equivalent to an approximately 7-dB threshold measured by method 2. These differences had major effects on the proportion of embolic signals detected with the use of the same decibel threshold but with intensity measured in the different ways. For example, using a threshold of 7 dB would result in only 4.9% of signals being missed by method 2 but 42.2% and 51.4% being missed by methods 1 and 3, respectively. Conclusions Our results demonstrate that the intensities of the same embolic signals, recorded with the same parameters, are markedly different when analyzed in the different ways used in previous studies. This has important implications when a decibel threshold is used and emphasizes that criteria developed by one investigator on one machine cannot be used by another investigator without initial reevaluation. This could account for some of the differences in frequencies of embolic signals reported in previous clinical studies.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3