An Approach for the Use of Doppler Ultrasound as a Screening Tool for Hemodynamically Significant Stenosis (Despite Heterogeneity of Doppler Performance)

Author:

Howard George1,Baker William H.1,Chambless Lloyd E.1,Howard Virginia J.1,Jones Anne M.1,Toole James F.1

Affiliation:

1. the Department of Public Health Sciences (G.H., J.F.T.) and the Stroke Center (G.H., V.J.H., A.M.J., J.F.T.), Bowman Gray School of Medicine of Wake Forest University, Winston-Salem, NC; Section of Vascular Surgery, Loyola University Medical School, Maywood, Ill (W.H.B.); and the Department of Biostatistics, University of North Carolina at Chapel Hill, Chapel Hill, NC (L.E.C.).

Abstract

Background and Purpose The Asymptomatic Carotid Atherosclerosis Study (ACAS) Doppler validation study assessed the performance of individual Doppler machines across a spectrum of laboratories. We attempted to establish a threshold specific to individual machines to predict angiographically defined hemodynamic stenosis. The reliability of these Doppler ultrasound criteria was prospectively and independently evaluated among patients screened with ultrasound in the ACAS trial. Methods Regression techniques were used to establish the relationship between Doppler velocity and percent stenosis by angiography for 63 specific Doppler machines. This relationship was used to establish a Doppler threshold to provide a 90% positive predictive value (PPV) of a 60% stenosis by angiography. The sensitivity of each Doppler machine to detect a 60% stenosis (at the 90% PPV threshold) was estimated. The efficacy of these Doppler thresholds was then prospectively evaluated by calculating the PPV among ACAS participants eligible by ultrasound. Results Of the 63 machines, 13 (21%) had an excellent sensitivity (80%+) at 90% PPV. In 32 devices (51%) only a marginal sensitivity (50% to 80%) could be achieved. In 9 devices (14%) the sensitivity was poor (0% to 50%), and in 9 (14%) no threshold could be established. Despite the heterogeneity of Doppler performance, the standardization program worked as designed in the ACAS trial. Of 825 surgical patients, 399 were eligible by Doppler and 395 subsequently underwent angiography. Of these, 32 (8.1%; 95% confidence interval, 5.4% to 10.8%) did not have hemodynamically significant stenosis by arteriography, a proportion nonsignificantly lower than the planned 10% by the PPV. Conclusions The performance of Doppler ultrasound was highly variable. This suggests that Doppler performance is likely overstated in the literature, but specific devices may perform satisfactorily to detect individuals with hemodynamically significant stenosis. Because performance differs substantially among devices, local investigators are strongly urged to maintain local standardization series. With such standardization, ultrasound performance is sufficient for admission to clinical trials and as the basis for carotid surgery. However, without quality control many ultrasound machines are not adequate to accurately predict the degree of carotid stenosis and should not be the only test to decide whether surgery is warranted.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3