Clinical Relevance of Intracranial Microembolic Signals in Patients With Left Ventricular Assist Devices

Author:

Nabavi D.G.1,Georgiadis D.1,Mumme T.1,Schmid C.1,Mackay T.G.1,Scheld H.H.1,Ringelstein E.B.1

Affiliation:

1. From the Departments of Neurology (D.G.N., D.G., T.M., E.B.R.) and of Thoracic and Cardiovascular Surgery (C.S., H.H.S.), University of Münster, Münster, Germany, and the University Department of Cardiac Surgery, Royal Infirmary, Glasgow, UK (T.G.M.).

Abstract

Background and Purpose The use of left ventricular assist devices has become an established method in bridging patients with end-stage cardiac failure to heart transplantation. Since thromboembolism is one of the major complications, we undertook this study to evaluate the clinical significance of Doppler microembolic signals (MES) in patients with left ventricular assist devices. Methods Six patients with left ventricular assist devices were monitored for MES with transcranial Doppler ultrasonography during the first 30 postoperative days. Additionally, repeated (10 per day and patient) and prolonged (3 hours per patient) monitorings were performed to assess the adequacy of the 30-minute recordings. Three observers evaluated 30 randomly assigned monitorings in a blinded fashion to assess the interobserver variability. The relation between MES counts and clinical, radiological, hemostaseological, and pump flow parameters and the predictive value of MES counts regarding the occurrence of embolic events was evaluated. Results Ten ischemic cerebrovascular accidents and 2 peripheral thromboembolic events occurred during the observation period of 177 days (total incidence, 6.8%). MES were found in 143 of 170 monitorings (84.1%). Their counts were significantly higher on days with clinically manifest embolic events as compared with event-free days (18.5 [3-74] versus 4 [0-52], respectively, median and 95% CI; P <.001, Mann-Whitney). The predictive value of MES counts above 7 per 30 minutes was high (75%). Significant differences in the incidence and counts of MES as well as in the incidence of clinically manifest embolic events were noted among the six patients (all P <.01) without equal differences in anticoagulant treatment or pump flow. Interobserver agreement was high ( P =.78 to .89, unpaired Student’s t test). Considerable short- and long-term intrapatient variations of MES counts, without consistent pattern, were noted. Conclusions Serial monitoring for MES is prognostically superior to single monitorings in patients with left ventricular assist devices. In the future, this new application mode may individually guide anticoagulation strategies and even influence the decision regarding early cardiac transplantation versus long-term use of the assist devices.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

Reference31 articles.

1. Annual report of the US Scientific Registry for organ transplantation and the organ procurement and transplantation network—1990. Es 8.-9. Washington DC: US Department of Health and Human Services.

2. Eight years' experience with bridging to cardiac transplantation

3. Ventricular Assist and Total Artificial Heart Devices for Clinical Use in 1993

4. Innovative Ventricular Assist Systems

Cited by 56 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3