Novel Sirolimus–Coated Balloon Catheter

Author:

Clever Yvonne Patricia1,Peters Daniel1,Calisse Jorge1,Bettink Stephanie1,Berg Madeleine-Caroline1,Sperling Christian1,Stoever Michael1,Cremers Bodo1,Kelsch Bettina1,Böhm Michael1,Speck Ulrich1,Scheller Bruno1

Affiliation:

1. From the Klinik für Innere Medizin III, Kardiologie, Angiologie und internistische Intensivmedizin, Universitätsklinikum des Saarlandes, Homburg/Saar, Germany (Y.P.C., S.B., B.C., M.B., B.S.); Institut für Radiologie, Charité—Universitätsmedizin Berlin, Campus Mitte, Humboldt Universität zu Berlin, Germany (D.P., B.K., U.S.); and B. Braun Melsungen AG, Berlin, Germany (J.C., M.-C.B., C.S., M.S.).

Abstract

Background— Limus-eluting stents are dominating coronary interventions, although paclitaxel is the only drug on balloon catheters with proven inhibition of restenosis. Neointimal inhibition by limus-coated balloons has been shown in few animal studies, but data from randomized clinical trials are not available. The aim of the present preclinical studies was to achieve high and persistent sirolimus levels in the vessel wall after administration by a coated balloon. Methods and Results— Different coating formulations and doses were studied in the porcine coronary model to investigate sirolimus tissue levels at different time points as well as efficacy at 1 month using quantitative coronary angiography and histomorphometry. Loss of the selected coating in the valve, guiding catheter, and blood was low (2±14% of dose). Acute drug transfer to the vessel wall was 14.4±4.6% with the crystalline coating, whereas the amorphous coatings were less effective in this respect. Persistence of sirolimus in the vessel wall until 1 month was 40% to 50% of the transferred drug. At 1-month follow-up, a modest but significant reduction of neointimal growth was demonstrated in a dose range from 4 μg/mm 2 to 2×7 μg/mm 2 , for example, maximum neointimal thickness of 0.38±0.13 versus 0.65±0.21 mm in the uncoated control group. Conclusions— Various sirolimus-coated balloons effectively reduce neointimal proliferation in the porcine coronary model but differ considerably in retention time in the vessel wall. It has to be determined if such a formulation with persistent high vessel concentration will result in a relevant clinical effect.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司