Serial Assessment of Strut Coverage of Biodegradable Polymer Drug-Eluting Stent at 1, 2, and 3 Months After Stent Implantation by Optical Frequency Domain Imaging

Author:

Chevalier Bernard1,Smits Pieter C.1,Carrié Didier1,Mehilli Julinda1,Van Boven Ad J.1,Regar Evelyn1,Sawaya Fadi J.1,Chamié Daniel1,Kraaijeveld Adriaan O.1,Hovasse Thomas1,Vlachojannis Georgios J.1

Affiliation:

1. From the Ramsay Générale de Santé, Interventional Cardiology Department, Institut Cardiovasculaire Paris Sud, Massy, France (B.C., F.J.S., T.H.); Department of Cardiology, Maasstad Hospital, Rotterdam, the Netherlands (P.C.S., A.O.K., G.J.V.); Department of Cardiology, CHU Rangueil, Toulouse, France (D.C.); Department of Cardiology, Munich University Clinic, LMU Munich and Munich Heart Alliance, DZHK, Germany (J.M.); Department of Cardiology, Medisch Centrum Leeuwarden, the Netherlands (A.J.V.B.);...

Abstract

Background— To assess the vessel-healing pattern of Ultimaster drug-eluting stent using optical frequency domain imaging. Our hypothesis is that biodegradable polymer-based drug-eluting technology allows complete very early strut coverage. Methods and Results— The DISCOVERY 1TO3 study (Evaluation With OFDI of Strut Coverage of Terumo New Drug Eluting Stent With Biodegradable Polymer at 1, 2, and 3 Months) is a prospective, single-arm, multicenter study. A total of 60 patients with multivessel disease requiring staged procedure at 1 month were treated with Ultimaster. Optical frequency domain imaging was acquired at baseline, 1, 2, and 3 months. The primary end point is optical frequency domain imaging–assessed strut coverage at 3 months. Mean age of patients was 67.2±9.9 years, and 73.3% were male, and 36.7% presented with acute coronary syndrome. A total of 132 lesions were treated, with average 1.4 lesions per patient treated at baseline and 1.1 lesions treated at 1 month. Strut coverage at 3 months of single implanted stents (n=71, primary end point) was 95.2±5.2% and of combined single and overlapped stents was 95.4±4.9%. Strut coverage of combined single and overlapped stents at 1 (n=49) and 2 months (n=38) was 85.1±12.7% and 87.9±10.8%, respectively. The median neointimal hyperplasia thickness was 0.04, 0.05, and 0.06 mm, whereas mean neointimal hyperplasia obstruction was 4.5±2.4%, 5.2±3.4%, and 6.6±3.3% at 1, 2, and 3 months, respectively. Conclusions— Nearly complete strut coverage was observed in this complex population very early after implantation of Ultimaster drug-eluting stent. Clinical Trial Registration— URL: https://www.clinicaltrials.gov . Unique identifier: NCT01844843.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Reference30 articles.

1. Risk of Stent Thrombosis Among Bare-Metal Stents, First-Generation Drug-Eluting Stents, and Second-Generation Drug-Eluting Stents

2. Pathology of Drug-Eluting Stents in Humans

3. 2017 ESC focused update on dual antiplatelet therapy in coronary artery disease developed in collaboration with EACTS: the task force for dual antiplatelet therapy in coronary artery disease of the European Society of Cardiology (ESC) and of the European Association for Cardio-Thoracic Surgery (EACTS) [published online ahead of print August 26, 2017].;Valgimigli M;Eur Heart J

4. Localized Hypersensitivity and Late Coronary Thrombosis Secondary to a Sirolimus-Eluting Stent

5. Biodegradable polymer drug-eluting stents reduce the risk of stent thrombosis at 4 years in patients undergoing percutaneous coronary intervention: a pooled analysis of individual patient data from the ISAR-TEST 3, ISAR-TEST 4, and LEADERS randomized trials.;Stefanini GG;Eur Heart J,2012

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3