Discordance Between Resting and Hyperemic Indices of Coronary Stenosis Severity

Author:

Hennigan Barry1,Oldroyd Keith G.1,Berry Colin1,Johnson Nils1,McClure John1,McCartney Peter1,McEntegart Margaret B.1,Eteiba Hany1,Petrie Mark C.1,Rocchiccioli Paul1,Good Richard1,Lindsay Martin M.1,Hood Stuart1,Watkins Stuart1

Affiliation:

1. From the University of Glasgow, United Kingdom (B.H., K.G.O., C.B., P.M., M.B.M., H.E., M.C.P., P.R., R.G., M.M.L., S.H., S.W.); Cardiology Department, Golden Jubilee National Hospital, Clydebank, Glasgow, United Kingdom (B.H., K.G.O., C.B., J.M.); and The Weatherhead PET Imaging Center, Houston, TX (N.J.).

Abstract

Background— Distal coronary to aortic pressure ratio (Pd/Pa) and instantaneous wave-free ratio (iFR) are indices of functional significance of a coronary stenosis measured without hyperemia. It has been suggested that iFR has superior diagnostic accuracy to Pd/Pa when compared with fractional flow reserve (FFR). We hypothesized that in comparison with FFR, revascularization decisions based on either binary cutoff values for iFR and Pd/Pa or hybrid strategies incorporating iFR or Pd/Pa will result in similar levels of disagreement. Methods and Results— This is a prospective study in consecutive patients undergoing FFR for clinical indications using proprietary software to calculate iFR. We measured Pd/Pa, iFR, FFR, and hyperemic iFR. Diagnostic accuracy versus FFR ≤0.80 was calculated using binary cutoff values of ≤0.90 for iFR and ≤0.92 for Pd/Pa, and adenosine zones for iFR of 0.86 to 0.93 and Pd/Pa of 0.87 to 0.94 in the hybrid strategy. One hundred ninety-seven patients with 257 stenoses (mean diameter stenosis 48%) were studied. Using binary cutoffs, diagnostic accuracy was similar for iFR and resting Pd/Pa with misclassification rates of 21% versus 20.2% ( P =0.85). In the hybrid analysis, 54% of iFR cases and 53% of Pd/Pa cases were outside the adenosine zone and rates of misclassification were 9.4% versus 11.9% ( P =0.55). Conclusions— Binary cutoff values for iFR and Pd/Pa result in misclassification of 1 in 5 lesions. Using a hybrid strategy, approximately half of the patients do not receive adenosine, but 1 in 10 lesions are still misclassified. The use of nonhyperemic indices of stenosis severity cannot be recommended for decision making in the catheterization laboratory. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT02377310.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 71 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3