Evolving Utilization of Covered Stents for Treatment of Aortic Coarctation: Report From the IMPACT Registry

Author:

Morray Brian H.1ORCID,Kennedy Kevin F.2,McElhinney Doff B.3ORCID

Affiliation:

1. Division of Pediatric Cardiology, Seattle Children’s Hospital, University of Washington, Seattle (B.H.M.).

2. Mid America Heart Institute, St. Luke’s Health System, Kansas City, MO (K.F.K.).

3. Department of Cardiothoracic Surgery, Lucile Packard Children’s Hospital at Stanford, Palo Alto, CA (D.B.M.).

Abstract

BACKGROUND: Covered stent (CS) use for the transcatheter treatment of coarctation of the aorta (COA) was first described over 20 years ago. The covered Cheatham-platinum stent received Food and Drug Administration approval for COA treatment in 2016. Data collected as part of the National Cardiovascular Data Registry IMPACT registry were evaluated for contemporary usage patterns of CS for the treatment of COA from 2016 to 2021. METHODS: Version 2 of the IMPACT registry was queried for all patients who underwent stent placement for treatment of COA from 2016 to 2021. Trends in CS use were evaluated by year and age of patient at the time of implant. Analysis was limited to clinical factors collected as part of the registry and was performed to identify factors associated with CS use. RESULTS: Data were available for 1989 case entries. Most patients (92%) received a single stent. The overall percentage of CS use in the cohort was 23% and remained consistent throughout the study period. The probability of CS use was significantly associated with increasing patient age at implant. Additional factors associated with CS use included smaller initial COA diameter, native COA, and the presence of a pseudoaneurysm. Procedural adverse event rates were low. CONCLUSIONS: CS use to treat COA was more common in adult patients and remained stable over the study period. Factors associated with CS use, including smaller COA diameter and aortic pseudoaneurysm, demonstrate the perceived value of CS as a tool to reduce the risk of aortic wall injury during treatment of COA.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Long Arc of Covered Stent Use in Coarctation of the Aorta in the United States;Circulation: Cardiovascular Interventions;2023-07

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3