Background: We investigated whether optical coherence tomography (OCT) guidance would reduce nonoptimal bioresorbable vascular scaffold (BVS) deployment. Methods: This was a randomized controlled trial. Patients who required percutaneous coronary intervention for ischemic heart disease were recruited from 2 centers in Korea. The enrolled patients were randomly assigned to receive either OCT-guided BVS (Absorb; Abbott Vascular) implantation or angiography-guided BVS implantation using an optimized technique. The primary outcome was nonoptimal deployment, which was a composite outcome of the following parameters assessed by OCT: a minimal scaffold area <5 mm 2 , residual area stenosis >20%, incomplete apposition of the scaffold struts >5%, major edge dissection, or scaffold disruption. The secondary outcome was a procedural complication defined by the occurrence of no reflow, coronary perforation, or flow-limiting dissection. Results: Between September 2016 and January 2018, 88 patients (90 lesions) were assigned to OCT guidance, while 88 patients (89 lesions) were assigned to angiography guidance. The recruitment was prematurely terminated in March 2018 because the manufacturer stopped supplying BVS. Postprocedural OCT data were available for 88 lesions with OCT guidance and for 88 lesions with angiography guidance. There was nonoptimal BVS deployment postprocedurally in 35.2% of patients in the OCT-guidance group and in 38.6% in the angiography-guidance group (absolute difference, −3.7% [95% CI, −19.0% to 11.6%]; P =0.64). There were no procedural complications in either group. Conclusions: OCT-guided BVS implantation did not reduce the incidence of nonoptimal deployment compared to that of angiography-guided BVS implantation (using optimized techniques). Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02894697.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3