The OCT-ORION Study

Author:

Lee Stephen W.L.1,Tam Frankie C.C.1,Lam Simon C.C.1,Kong Shun-Ling1,Shea Catherine P.1,Chan Kelvin K.W.1,Wong Michael K.L.1,Chan Michael P.H.1,Wong Anthony Y.T.1,Yung Arthur S.Y.1,Lam Yui-Ming1,Zhang Lei-Wei1,Wu Karl K.Y.1,Mintz Gary S.1,Maehara Akiko1

Affiliation:

1. From the Division of Cardiology, Department of Medicine, University of Hong Kong, Queen Mary Hospital, Pok Fu Lam, Hong Kong (S.W.L.L., F.C.C.T., S.C.C.L., S.-L.K., C.P.S., K.K.W.C., M.K.L.W., M.P.H.C., A.Y.T.W., A.S.Y.Y., Y.-M.L., L.-W.Z., K.K.Y.W.); Clinical Trials Center, Cardiovascular Research Foundation, New York, NY (G.S.M., A.M.); and NewYork-Presbyterian Hospital/Columbia University Medical Center (A.M.).

Abstract

Background— Durable polymers used in drug-eluting stents are considered a potential cause of hypersensitivity inflammatory response adversely affecting stent healing. Using a sequential follow-up with optical coherence tomography, we compared the differences in healing profiles of 2 drug-eluting stents with a biodegradable or durable polymer. Methods and Results— Sixty patients with multivessel disease were prospectively enrolled to receive both study stents, which were randomly assigned to 2 individual vessels, a Resolute Integrity zotarolimus-eluting stent with a durable BioLinx polymer and a BioMatrix NeoFlex Biolimus A9–eluting stent with a biodegradable polylactic acid polymer. Optical coherence tomography was performed at baseline, then in 5 randomly assigned monthly groups at 2 to 6 months, and at 9 months in all patients. The primary end point was the difference in optical coherence tomography strut coverage at 9 months. Key secondary end points included angiographic late lumen loss and composite major adverse cardiac events (cardiac death, myocardial infarction, target lesion revascularization, and definite or probable stent thrombosis) at 9 months. Resolute Integrity zotarolimus-eluting stent showed significantly better strut coverage than BioMatrix NeoFlex Biolimus A9–eluting stent at 2 to 6 months ( P <0.001) and less variance of percent coverage at 9 months, 99.7% (interquartile range, 99.1–100) versus 99.6% (interquartile range, 96.8–99.9; difference, 0.10; 95% confidence interval, 0.00–1.05; P <0.001). No significant difference was observed in major adverse cardiac events or angiographic end points. Conclusions— Despite having a durable polymer, Resolute Integrity zotarolimus-eluting stent exhibited better strut coverage than BioMatrix NeoFlex Biolimus A9–eluting stent having a biodegradable polymer; both showed similar antiproliferative efficacy. This novel, longitudinal, sequential optical coherence tomography protocol using each patient as own control could achieve conclusive results in small sample size. Clinical Trial Registration— URL: https://www.clinicaltrials.gov . Unique identifier: NCT01742507.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3