Pulsatile Flow in Patients With a Novel Nonpulsatile Implantable Ventricular Assist Device

Author:

Potapov Evgenij V.1,Loebe Matthias1,Nasseri Boris A.1,Sinawski Hendryk1,Koster Andreas1,Kuppe Hermann1,Noon George P.1,DeBakey Michael E.1,Hetzer Roland1

Affiliation:

1. From the Deutsches Herzzentrum Berlin (E.V.P., M.L., B.A.N., H.S., A.K., H.K., R.H.), Berlin, Germany; and Baylor College of Medicine (G.P.N., M.E.D.), Houston, Tex.

Abstract

Background —Ventricular assist devices (VADs) are an accepted therapy for patients with end-stage heart failure. The implantable devices that are available produce a pulsatile flow and are very large. In 6 patients, beginning in November 1998, we started to use the continuous-flow implantable DeBakey VAD device, which weighs 93 g. To detect the flow in peripheral vessels, we measured transcranial Doppler signals in patients after implantation. Methods and Results —Transcranial Doppler studies were performed with the MULTI-DOP X4 device with two 2-MHz probes (for the middle cranial arteries) in 4 patients for up to 12 weeks twice weekly after implantation. The blood velocity was measured, and the pulsation index (PI) calculated. The measured pump flow and rotations per minute were registered. The preoperative echocardiographic assessment values were compared with those acquired 6 weeks after implantation. The PI increased continually in all patients after VAD implantation, left ventricular (LV) ejection fraction did not improve, but right ventricular (RV) ejection fraction after implantation improved compared with preoperative values. The LV end-diastolic diameter after implantation decreased between 11% and 46% intraindividually. There was no correlation between PI and blood pressure or, except in 1 patient, between PI and blood flow through the VAD. Conclusions —The DeBakey VAD unloads the LV, which leads to a decrease in LV end-diastolic LV diameter and to the restoration of RV function. The unloaded LV and partially recovered RV provide a nearly physiological pulsatile flow despite the continuous flow of the VAD. Pulsatility is independent of peripheral vascular resistance. The first clinical experience with the DeBakey VAD was positive and has resulted in its continued use.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3