Prospectively Randomized Comparison of Different Mechanical Aortic Valves

Author:

Autschbach Rüdiger1,Walther Thomas1,Falk Volkmar1,Kostelka Martin1,Rösler Annegret1,Langebartels Georg1,Krüger Martin1,Diegeler Anno1,Mohr Friedrich W.1

Affiliation:

1. From the Universität Leipzig, Herzzentrum, Klinik für Herzchirurgie, Leipzig, Germany.

Abstract

Background —The aim of this prospectively randomized study was to evaluate the hemodynamic and functional outcomes after aortic valve replacement with 3 different bileaflet mechanical valves. Methods and Results —Three hundred consecutive patients were randomly assigned to receive ATS (n=100), Carbomedics (n=100), or St Jude Medical Hemodynamic Plus (n=100) mechanical aortic valve replacement. There were no significant differences regarding patient age (average 61±8 years), body surface area (1.9±0.2 m 2 ), left ventricular function (ejection fraction 0.59±0.17), and presence of aortic stenosis (90%, 89%, and 91%), respectively. All patients had postoperative as well as 6-month and 1-year follow-ups that included transthoracic echocardiography. Multivariate statistical analysis was performed. Implanted valve sizes were comparable at 24±2 (ATS), 23.7±1.6 (CM), and 23.6±1.9 (SJM HP ) mm (NS). At 1-year follow-up, the following incidence of events was noted: death 3/1/1, all non–valve related; stroke 0/1/1; trivial transvalvular incompetence 3/3/2; paravalvular leak 2/3/2; and reoperation 0/1/1, respectively (NS). Transvalvular flow velocities were 2.5/2.6/2.4 m/s postoperatively ( P =0.03) and 2.4/2.4/2.3 m/s at 6-month follow-up, respectively (NS). There was a significant decrease in left ventricular mass for all patients but no significant differences among the groups. Conclusions —There are no clinically relevant differences among the tested bileaflet aortic valves. Regardless of valve type, there was a low complication rate. On the basis of these findings, all 3 bileaflet prostheses are well suited for aortic valve replacement.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference24 articles.

1. Bodnar E. Mechanical valves. In: Acar J Bodnar E eds. Textbook of Acquired Heart Valve Disease . London UK: ICR Publishers; 1995:965–1001.

2. Yoganathan AP Wick TM Reul H. The influence of flow characteristics of prosthetic valves on thrombus formation. In: Butchart E Bodnar E eds. Thrombosis Embolism and Bleeding . London UK: ICR Publishers; 1992:123–148.

3. Where is the ideal heart valve substitute? What has frustrated its realization?

4. Modern Cardiac Valve Devices? Bioprostheses and Mechanical Prostheses: State of the Art

5. The Evolution of Artificial Heart Valves

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献