Factors Affecting Longevity of Homograft Valves Used in Right Ventricular Outflow Tract Reconstruction for Congenital Heart Disease

Author:

Tweddell James S.1,Pelech Andrew N.1,Frommelt Peter C.1,Mussatto Kathleen A.1,Wyman John D.1,Fedderly Raymond T.1,Berger Stuart1,Frommelt Michele A.1,Lewis David A.1,Friedberg David Z.1,Thomas John P.1,Sachdeva Ramesh1,Litwin S. Bert1

Affiliation:

1. From the Department of Surgery (Cardiothoracic Surgery), Pediatrics (Cardiology), and the Center for Outcomes Research and Quality Management, Children’s Hospital of Wisconsin, Medical College of Wisconsin, Milwaukee, Wis.

Abstract

Background —Few studies have explored the long-term function of cryopreserved homograft valves used for reconstruction of the right ventricular tract (RVOT) in patients with congenital heart disease. Methods and Results —Among 205 patients receiving cryopreserved homografts for reconstruction of the RVOT between November 1985 and April 1999, the outcome of 220 homografts in 183 operative survivors was analyzed. There were 150 pulmonary and 70 aortic homografts used. Median age at implantation was 4.4 years (mean 6.9±7.6 years, range 3 days to 48 years). End points included (1) patient survival, (2) homograft failure (valve explant or late death), and (3) homograft dysfunction (homograft insufficiency or homograft stenosis). Survival was 88% at 10 years. Freedom from homograft failure was 74±4% at 5 years and 54±7% at 10 years. Univariable analysis identified younger age, longer donor warm ischemic time, valve Z value <2, and previous procedure as risk factors for homograft failure and dysfunction. Aortic homograft type and extracardiac operative technique predicted homograft failure but not dysfunction. For patients ≤1 year of age, valve type did not predict failure or dysfunction. Multivariable analysis identified younger age and longer donor warm ischemic time as risk factors for homograft failure and dysfunction, whereas, Z value <2 and aortic valve type predicted homograft valve failure. Conclusions —Homograft valves used for RVOT reconstruction provide effective intermediate palliation with excellent late survival. Factors that adversely affect graft longevity include younger age, longer donor warm ischemic time, smaller homograft size, use of aortic homograft in the older patient, and extracardiac operative technique.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3