Fractional Flow Reserve Compared With Intravascular Ultrasound Guidance for Optimizing Stent Deployment

Author:

Fearon William F.1,Luna Jorge1,Samady Habib1,Powers Eric R.1,Feldman Ted1,Dib Nabil1,Tuzcu E. Murat1,Cleman Michael W.1,Chou Tony M.1,Cohen David J.1,Ragosta Michael1,Takagi Atsushi1,Jeremias Allen1,Fitzgerald Peter J.1,Yeung Alan C.1,Kern Morton J.1,Yock Paul G.1

Affiliation:

1. From Stanford University Medical Center (W.F.F., J.L., A.T., P.J.F., A.C.Y., P.G.Y.), Stanford, Ca; University of Virginia Medical Center (H.S., E.R.P., M.R.), Charlottesville; University of Chicago Hospital (T.F.), Chicago, Ill; Arizona Heart Institute (N.D.), Phoenix; Cleveland Clinic Foundation (E.M.T., A.J.), Cleveland, Ohio; Yale University Hospital (M.W.C.), New Haven, Conn; UCSF Moffitt-Long Hospitals (T.M.C.), San Francisco, Calif; Beth Israel Deaconess Medical Center (D.J.C.), Boston, Mass;...

Abstract

Background Determination of fractional flow reserve (FFR) has been proposed as a means to assess stent deployment. In this prospective, multicenter trial, we evaluate the use of FFR to optimize stenting by comparing it with standard intravascular ultrasound (IVUS) criteria. Methods and Results Eighty-four stable patients with isolated coronary lesions underwent coronary stent deployment starting at 10 atm and increased serially by 2 atm until the FFR was ≥0.94 or 16 atm was achieved. IVUS was then performed. FFR was measured with a coronary pressure wire with intracoronary adenosine to induce hyperemia. The diagnostic characteristics of an FFR <0.94 to predict suboptimal stent expansion by IVUS, defined in both absolute and relative terms, were calculated. Over a range of IVUS criteria, the highest sensitivity, specificity, and predictive accuracy of FFR were 80%, 30%, and 42%, respectively. Receiver operator characteristic analysis defined an optimal FFR cut point at ≥0.96; at this threshold, the sensitivity, specificity, and predictive accuracy of FFR were 75%, 58%, and 62%, respectively ( P =0.03 for comparison of predictive accuracy, P =0.01 for concordance between FFR and IVUS). The negative predictive value was 88%. Significantly better diagnostic performance was achieved in a subgroup that received higher doses (>30 μg) of intracoronary adenosine during pressure measurements, suggesting that FFR might be overestimated in the other group. Conclusions A fractional flow reserve <0.96, measured after stent deployment, predicts a suboptimal result based on validated intravascular ultrasound criteria; however, an FFR ≥0.96 does not reliably predict an optimal stent result. Higher doses of intracoronary adenosine than previously used to measure FFR improve these results.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3