Smartphone-Based Blood Pressure Measurement Using Transdermal Optical Imaging Technology

Author:

Luo Hong1,Yang Deye1,Barszczyk Andrew2,Vempala Naresh3,Wei Jing1,Wu Si Jia3,Zheng Paul Pu3,Fu Genyue4,Lee Kang35,Feng Zhong-Ping2

Affiliation:

1. The Affiliated Hospital of Hangzhou Normal University (H.L., D.Y., J.W.), Hangzhou Normal University, Zhejiang, China.

2. Department of Physiology (A.B., Z.-P.F.), University of Toronto, ON, Canada.

3. Dr Eric Jackman Institute of Child Study (N.V., S.J.W., P.P.Z., K.L.), University of Toronto, ON, Canada.

4. Department of Psychology (G.F.), Hangzhou Normal University, Zhejiang, China.

5. Department of Psychology, Zhejiang Normal University, Jinhua, China (K.L.).

Abstract

Background: Cuff-based blood pressure measurement lacks comfort and convenience. Here, we examined whether blood pressure can be determined in a contactless manner using a novel smartphone-based technology called transdermal optical imaging. This technology processes imperceptible facial blood flow changes from videos captured with a smartphone camera and uses advanced machine learning to determine blood pressure from the captured signal. Methods: We enrolled 1328 normotensive adults in our study. We used an advanced machine learning algorithm to create computational models that predict reference systolic, diastolic, and pulse pressure from facial blood flow data. We used 70% of our data set to train these models and 15% of our data set to test them. The remaining 15% of the sample was used to validate model performance. Results: We found that our models predicted blood pressure with a measurement bias±SD of 0.39±7.30 mm Hg for systolic pressure, −0.20±6.00 mm Hg for diastolic pressure, and 0.52±6.42 mm Hg for pulse pressure, respectively. Conclusions: Our results in normotensive adults fall within 5±8 mm Hg of reference measurements. Future work will determine whether these models meet the clinically accepted accuracy threshold of 5±8 mm Hg when tested on a full range of blood pressures according to international accuracy standards.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging

Cited by 153 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3