Real-Time Artificial Intelligence–Based Guidance of Echocardiographic Imaging by Novices: Image Quality and Suitability for Diagnostic Interpretation and Quantitative Analysis

Author:

Mor-Avi Victor1ORCID,Khandheria Bijoy2,Klempfner Robert3ORCID,Cotella Juan I.1,Moreno Merav3,Ignatowski Denise2,Guile Brittney1,Hayes Hailee J.2,Hipke Kyle1,Kaminski Abigail2ORCID,Spiegelstein Dan4,Avisar Noa4,Kezurer Itay4,Mazursky Asaf5,Handel Ran6,Peleg Yotam6ORCID,Avraham Shir5,Ludomirsky Achiau7,Lang Roberto M.1

Affiliation:

1. University of Chicago Medical Center, IL (V.M.-A., J.I.C., B.G., K.H., R.M.L.).

2. Cardiovascular Research, Advocate Aurora Research, Milwaukee, WI (B.K., D.I., H.J.H., A.K.).

3. Department of Cardiology, Cardiac Rehabilitation Institute, Sheba Medical Center, Israel (R.K., M.M.).

4. UltraSight, Ltd, Rehovot, Israel (D.S., N.A., I.K.).

5. Faculty of Medicine, Ben-Gurion University of the Negev, Beer-Sheva, Israel (A.M., S.A.).

6. Azrieli Faculty of Medicine in the Galilee Bar-Ilan University, Safed, Israel (R.H., Y.P.).

7. NYU Langone Health, New York (A.L.).

Abstract

BACKGROUND: We aimed to assess in a prospective multicenter study the quality of echocardiographic exams performed by inexperienced users guided by a new artificial intelligence software and evaluate their suitability for diagnostic interpretation of basic cardiac pathology and quantitative analysis of cardiac chamber and function. METHODS: The software (UltraSight, Ltd) was embedded into a handheld imaging device (Lumify; Philips). Six nurses and 3 medical residents, who underwent minimal training, scanned 240 patients (61±16 years; 63% with cardiac pathology) in 10 standard views. All patients were also scanned by expert sonographers using the same device without artificial intelligence guidance. Studies were reviewed by 5 certified echocardiographers blinded to the imager’s identity, who evaluated the ability to assess left and right ventricular size and function, pericardial effusion, valve morphology, and left atrial and inferior vena cava sizes. Finally, apical 4-chamber images of adequate quality, acquired by novices and sonographers in 100 patients, were analyzed to measure left ventricular volumes, ejection fraction, and global longitudinal strain by an expert reader using conventional methodology. Measurements were compared between novices’ and experts’ images. RESULTS: Of the 240 studies acquired by novices, 99.2%, 99.6%, 92.9%, and 100% had sufficient quality to assess left ventricular size and function, right ventricular size, and pericardial effusion, respectively. Valve morphology, right ventricular function, and left atrial and inferior vena cava size were visualized in 67% to 98% exams. Images obtained by novices and sonographers yielded concordant diagnostic interpretation in 83% to 96% studies. Quantitative analysis was feasible in 83% images acquired by novices and resulted in high correlations (r≥0.74) and small biases, compared with those obtained by sonographers. CONCLUSIONS: After minimal training with the real-time guidance software, novice users can acquire images of diagnostic quality approaching that of expert sonographers in most patients. This technology may increase adoption and improve accuracy of point-of-care cardiac ultrasound.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3