Feasibility of Cardiovascular Magnetic Resonance to Assess the Orifice Area of Aortic Bioprostheses

Author:

von Knobelsdorff-Brenkenhoff Florian1,Rudolph André1,Wassmuth Ralf1,Bohl Steffen1,Buschmann Eva Elina1,Abdel-Aty Hassan1,Dietz Rainer1,Schulz-Menger Jeanette1

Affiliation:

1. From the Franz-Volhard-Klinik for Cardiology, HELIOS Klinikum Berlin Buch, University Medicine Berlin, Charité Campus Buch, Berlin, Germany.

Abstract

Background— Prosthetic orifice area, usually calculated by transthoracic echocardiography (TTE) or transesophageal echocardiography (TEE), provides important information regarding the hemodynamic performance of aortic bioprostheses. However, both TTE and TEE have limitations; therefore accurate and reproducible determination of the orifice area often remains a challenge. The present study aimed to investigate the feasibility of cardiovascular magnetic resonance (CMR) to assess the orifice areas of aortic bioprostheses. Methods and Results— CMR planimetry of the orifice area was performed in 65 patients (43/22 stented/stentless prostheses; mean time since implantation, 3.1�2.8 years; mean orifice area [TTE], 1.70�0.43 cm 2 ; 62 normally functioning prostheses, 2 severe stenoses, and 1 severe regurgitation) in an imaging plane perpendicular to the transprosthetic flow using steady-state free-precession cine imaging under breath-hold conditions on a 1.5-T MR system. CMR results were compared with TTE (continuity equation, n=65) and TEE (planimetry, n=31). CMR planimetry was readily feasible in 80.0%; feasible with limitation in 15.4% because of stent, flow, and sternal wire artifacts; and impossible in 4.6% because of flow artifacts. Correlations of the orifice areas by CMR with TTE ( r =0.82) and CMR with TEE ( r =0.92) were significant. The average difference between the methods was −0.02�0.24 cm 2 (TTE) and 0.05�0.15 cm 2 (TEE). Agreement was present for stented and stentless devices and independent of orifice size. Intraobserver and interobserver variabilities of CMR planimetry were 6.7�5.4% and 11.5�7.8%. Conclusions— The assessment of aortic bioprostheses with normal orifice areas by CMR is technically feasible and provides orifice areas with a close correlation to echocardiography and low observer dependency.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3