Integrated Myocardial Perfusion Imaging Diagnostics Improve Detection of Functionally Significant Coronary Artery Stenosis by 13 N-ammonia Positron Emission Tomography

Author:

Lee Joo Myung1,Kim Chee Hae1,Koo Bon-Kwon1,Hwang Doyeon1,Park Jonghanne1,Zhang Jinlong1,Tong Yaliang1,Jeon Ki-Hyun1,Bang Ji-In1,Suh Minseok1,Paeng Jin Chul1,Cheon Gi Jeong1,Na Sang-Hoon1,Ahn Jung-Min1,Park Seung-Jung1,Kim Hyo-Soo1

Affiliation:

1. From the Division of Cardiology, Department of Internal Medicine, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea (J.M.L.); Department of Internal Medicine, Cardiovascular Center (C.H.K., B.-K.K., D.H., J.P., J.Z., Y.T., H.-S.K.), Department of Nuclear Medicine (J.-I.B., M.S., J.C.P., G.J.C.), and Department of Internal Medicine, Emergency Medical Center (S.-H.N.), Seoul National University Hospital, Korea; Institute of Aging, Seoul...

Abstract

Background— Recent evidence suggests that the diagnostic accuracy of myocardial perfusion imaging is improved by quantifying stress myocardial blood flow (MBF) in absolute terms. We evaluated a comprehensive quantitative 13 N-ammonia positron emission tomography ( 13 NH 3 -PET) diagnostic panel, including stress MBF, coronary flow reserve (CFR), and relative flow reserve (RFR) in conjunction with relative perfusion defect (PD) assessments to better detect functionally significant coronary artery stenosis. Methods and Results— A total of 130 patients (307 vessels) with coronary artery disease underwent both 13 NH 3 -PET and invasive coronary angiography with fractional flow reserve (FFR) measurement. Diagnostic accuracy, optimal cut points, and discrimination indices of respective 13 NH 3 -PET quantitative measures were compared, with FFR as standard reference. The capacity to discern disease with stepwise addition of stress MBF, CFR, and RFR to qualitatively assessed relative PD was also gauged, using the category-free net reclassification index. All quantitative measures showed significant correlation with FFR (PET-derived CFR, r =0.388; stress MBF, r =0.496; and RFR, r =0.780; all P <0.001). Optimal respective cut points for FFR ≤0.8 and ≤0.75 were 1.99 and 1.84 mL/min per g for stress MBF and 2.12 and 2.00 for PET-derived CFR. Discrimination indices of quantitative measures that correlated with FFR ≤0.8 were all significantly higher than that of relative PD (area under the curve: 0.626, 0.730, 0.806, and 0.897 for relative PD, CFR, stress MBF, and RFR, respectively; overall comparison P <0.001). The capacity for functionally significant coronary stenosis was incrementally improved by the successive addition of CFR (net reclassification index=0.629), stress MBF (net reclassification index=0.950), and RFR (net reclassification index=1.253; all P <0.001) to relative PD. Conclusions— Integrating quantitative 13 NH 3 -PET measures with qualitative myocardial perfusion assessment provides superior diagnostic accuracy and improves the capacity to detect functionally significant coronary artery stenosis. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifiers: NCT01621438 and NCT01366404.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3