What Is the Most Appropriate Methodology for Detection of Conduit Artery Endothelial Dysfunction?

Author:

Guthikonda Sasidhar1,Sinkey Christine A.1,Haynes William G.1

Affiliation:

1. From the Department of Cardiology (S.G.), Baylor College of Medicine, Houston, Tex; and the Department of Internal Medicine and General Clinical Research Center (C.A.S., W.G.H.), University of Iowa College of Medicine, Iowa City.

Abstract

Background— Use of upper-arm arterial occlusion to induce reactive hyperemia, and endothelium-dependent flow-mediated dilation (FMD) of the brachial artery, induces greater conduit vessel dilatation than lower-arm occlusion. However, brachial artery ischemia after upper arm arterial occlusion may make this approach unreliable. We studied whether upper or lower arm occlusions differ in their ability to detect endothelial dysfunction in cigarette smokers, and its improvement with an antioxidant strategy. Methods and Results— Ten cigarette smokers with a >20 pack year history and 10 age- and gender-matched healthy controls participated in a 2-phase randomized controlled study of xanthine oxidase inhibition, using a 600-mg oral dose of allopurinol administered beforehand. Endothelium-dependent dilatation was assessed using ultrasound-Doppler after lower and upper arm occlusion. After lower arm occlusion, FMD was significantly impaired in smokers compared with controls (3.8±1.1% versus 8.7±2.2%; P =0.001). However, after upper arm occlusion, brachial artery dilatation in smokers was higher (11.8±2.7%; P <0.0001 versus lower arm) and did not differ from controls (9.4±2.9%; P =0.3). There was no difference in endothelium-independent dilatation to sublingual nitroglycerin between smokers and controls. Inhibition of xanthine oxidase with allopurinol improved lower arm FMD (3.8±1.1 to 10.1±1.9%; P <0.0001), but did not improve upper arm FMD (11.8±2.7 to 14.1±3.7%; P =0.4). Conclusions— Although upper arm occlusion induces robust brachial vasodilatation, it cannot detect endothelial dysfunction induced by smoking or its improvement by inhibition of xanthine oxidase. The increase in brachial artery diameter with upper arm occlusion may be confounded by ischemia of the artery. Conduit artery FMD after release of lower arm occlusion appears to be a more valid method for assessment of endothelial function in humans.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3