Number Needing Review: A Novel Metric to Assess Triage Efficiency of Large Vessel Occlusion Detection Systems

Author:

Catapano Joshua S.1,Lee Katriel E.1,Desai Shashvat M.1,Rangel India C.1,Stonnington Henry O.1,Rumalla Kavelin1,Rutledge Caleb1,Srinivasan Visish M.1,Baranoski Jacob F.1,Cole Tyler S.1,Winkler Ethan A.1,Ducruet Andrew F.1,Albuquerque Felipe C.1,Jadhav Ashutosh P.1ORCID

Affiliation:

1. Department of Neurosurgery, Barrow Neurological Institute St. Joseph's Hospital and Medical Center Phoenix Arizona

Abstract

Background Endovascular thrombectomy is the gold‐standard treatment for large vessel occlusions (LVOs). A novel metric is introduced: the number needing review (NNR) to assess the triage efficiency of LVO detection systems. Methods Patients with suspected ischemic stroke and images processed by RapidAI LVO detection software over 6 months were reviewed. Only patients with LVOs of the M1 segment were included. The NNR was calculated for an M1 occlusion. Results Of 559 patients, M1 occlusion was detected in 42 patients (7.5%). RapidAI LVO had a sensitivity of 71%, specificity of 94%, positive predictive value of 49%, and negative predictive value of 92% for M1 occlusion. When gaze deviation and hyperdense sign were combined with RapidAI LVO, the specificity and positive predictive value increased to 100% for an M1 occlusion. A negative RapidAI LVO result combined with a low (<15 mL, T max >6 seconds) or high (<50 mL, T max >6 seconds) T max threshold was found to have a specificity and positive predictive value of 100% for no occlusion. The combination of gaze deviation, hyperdense sign, positive RapidAI LVO, and negative RapidAI LVO with low T max threshold yielded an NNR of 24 per 100 cases. When combined with a negative RapidAI LVO and a high T max threshold, the NNR was 16 per 100 cases. Adding National Institutes of Health Stroke Scale score <7 decreased the NNR to 9 per 100 cases. Conclusion Adding gaze deviation and hyperdense sign to the RapidAI LVO increases the specificity and positive predictive value for an M1 occlusion. When combined with a negative RapidAI LVO detection and either a low or high T max >6 seconds threshold, the NNR is significantly reduced.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3