Prevention of Distal Embolization During Coronary Angioplasty in Saphenous Vein Grafts and Native Vessels Using Porous Filter Protection

Author:

Grube Eberhard1,Gerckens Ulrich1,Yeung Alan C.1,Rowold Sascha1,Kirchhof Nicole1,Sedgewick Jerry1,Yadav Jay S.1,Stertzer Simon1

Affiliation:

1. From the Department of Cardiology/Angiology, Heart Center Siegburg, Siegburg, Germany (E.G., U.G., S.R.); the Division of Cardiovascular Medicine, Stanford University, Stanford, Calif (A.C.Y., S.S.); the University of Minnesota, Minneapolis (N.K., J.S.); and the Departments of Cardiology and Molecular Cardiology and the Joseph J. Jacobs Center for Thrombosis and Vascular Biology, The Cleveland Clinic Foundation, Cleveland, Ohio (J.S.Y.).

Abstract

Background Although distal embolization and the “no-reflow” phenomenon are well described in saphenous vein graft (SVG) interventions, the frequency, magnitude, and characterization of embolized debris have not been evaluated in routine coronary interventions. A unique embolus protection device described herein provides a means of containing and retrieving plaque material dislodged during percutaneous coronary interventions. This report details the first clinical experience of the effectiveness and safety of an emboli protection system in 11 SVG lesions and 15 native coronary artery lesions. Methods and Results The AngioGuard Emboli Capture Guidewire (Cordis) consists of a PTCA wire with an expandable filter at the distal tip. The porous membrane permits normal distal blood flow, while trapping potential emboli by filtration. After crossing the lesion, the filter is expanded, and routine angioplasty is performed over the same wire. Emboli retrieval is achieved by collapsing the filter and retracting the emboli capture wire (ECW). In 26 patients, standard angioplasty was performed over the ECW; 20 of these 26 patients received a stent. Collected debris was sent for histopathological analysis. Plaque debris was retrieved after native coronary and SVG interventions in all cases. The ECW was positioned and retrieved without complications. No major adverse events occurred. Myocardial infarctions and no-reflow were not observed. Conclusions The embolization of plaque fragments frequently occurs during coronary and SVG intervention. Distal embolization leading to microvascular obstruction and no-reflow could be successfully minimized by using the ECW.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 158 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3