Transvascular intracardiac applications of a miniaturized phased-array ultrasonic endoscope. Initial experience with intracardiac imaging in piglets.

Author:

Valdes-Cruz L M1,Sideris E1,Sahn D J1,Murillo-Olivas A1,Knudson O1,Omoto R1,Kyo S1,Gulde R1

Affiliation:

1. Department of Pediatrics, University of California, San Diego Medical Center.

Abstract

BACKGROUND Recent advances in miniaturization of phased-array and mechanical ultrasound devices have resulted in exploration of alternative approaches to cardiac and vascular imaging in the form of transesophageal or intravascular imaging. Preliminary efforts in adapting phased-array endoscopes designed for transesophageal use to a transvascular approach have used full-sized phased-array devices introduced directly into the right atrium in open-chested animals. The purpose of this study was to assess the feasibility of using a custom-made, very small phased-array endoscope for intracardiac imaging introduced intravascularly through a jugular venous approach in young piglets. METHODS AND RESULTS Experimental atrial septal defects created in four piglets (3-4 weeks old) had been closed with a buttoned atrial septal defect closure device consisting of an occluder in the left atrium and a counteroccluder in the right atrium. Five to 15 days after atrial septal defect closure, the piglets were returned to the experimental laboratory, where a 6.3-mm, 17-element, 5-MHz phased-array probe mounted on a 4-mm endoscope was introduced through a cutdown incision of the external jugular vein and advanced to the right atrium. From the right atrium all four cardiac chambers, their inflows and outflows, and all four valves were well imaged with minimal superior and inferior rotation. High-resolution imaging of the atrial septum defined with anatomical accuracy, later verified by autopsy, the exact placement of both the occluder and counteroccluder in the left and right sides of the atrial septal defects and the absence of any shunting across the atrial septum in any of the four animals. CONCLUSIONS Our efforts indicate that transvascular passage of small phased-array probes can be easily accomplished and is a promising technique for detailed visualization of cardiac structures. This approach may provide an alternative to transesophageal echocardiography, particularly for guiding interventional procedures such as placement of transcatheter closure devices in pediatric patients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 32 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3