Effect of epicardial patch electrodes on transthoracic defibrillation.

Author:

Lerman B B1,Deale O C1

Affiliation:

1. Department of Medicine, New York Hospital-Cornell University Medical Center, NY 10021.

Abstract

To improve survival rates in patients undergoing surgical ablative procedures for malignant ventricular tachycardia (VT), a frequent practice is to implant epicardial patch electrodes at the time of map-guided surgery. After operation, patients with inducible VT often receive an automatic internal cardioverter/defibrillator (AICD) implant, whereas patients with noninducible VT usually do not. In the event that spontaneous, hypotensive VT or ventricular fibrillation should subsequently occur in the patient with noninducible VT, however, transthoracic defibrillation and resuscitation may prove difficult, because the patch electrodes are insulated with silicone rubber that can reduce the amount of current traversing the myocardium and thus can increase transthoracic defibrillation threshold (DFT). In this study, DFT was determined in mongrel dogs to test the hypothesis that epicardial patch electrodes elevate threshold. This study was also designed to assess the effect of patch electrode orientation and size on DFT. In the first protocol (perpendicular orientation), small epicardial patch electrodes (surface area, 30 cm2) were sutured to the epicardial surfaces of the anterior right and posterior left ventricles in 15 dogs so that the center axes of the patch electrodes were coincident and perpendicular to the coincident center axes of the transthoracic electrodes. The effect of two large epicardial patch electrodes (surface area, 53 cm2) on transthoracic DFT was also examined in eight of these dogs. In the second protocol (parallel orientation), small patch electrodes were sutured to the lateral surfaces of the right and left ventricles in seven dogs.(ABSTRACT TRUNCATED AT 250 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference17 articles.

1. Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator.

2. Annual Post-FDA Approval Report on the Automatic Implantable Cardioverter Defibrillator (AICD) System: Cardiac Pacemakers February 15 1988

3. The Treatment of Malignant Ventricular Arrhythmias with Combined Endocardial Resection and Implantation of the Automatic Defibrillator: Preliminary Report

4. Treatment of Malignant Ventricular Arrhythmias with Endocardial Resection and Implantation of the Automatic Cardioverter-Defibrillator

5. Winkle RA Thomas A: The automatic implantable cardioverter defibrillator: The US experience in Brugada P Wellens HJJ (eds): Cardiac Arrhythmias: Where to Go from Here? Mount Kisco New York Futura Publishing 1987 pp 663-680