Assessment of severity of mitral regurgitation by measuring regurgitant jet width at its origin with transesophageal Doppler color flow imaging.

Author:

Tribouilloy C1,Shen W F1,Quéré J P1,Rey J L1,Choquet D1,Dufossé H1,Lesbre J P1

Affiliation:

1. Department of Cardiology, South Hospital, University of Picardie, Amiens, France.

Abstract

BACKGROUND The ability of transesophageal color Doppler echocardiography to provide high-resolution images of both cardiac structure and blood flow in real time is advantageous for many clinical purposes. This study was performed to determine the utility of the regurgitant jet width at its origin measured by transesophageal Doppler color flow imaging in the assessment of severity of mitral regurgitation. METHODS AND RESULTS Sixty-three consecutive patients with mitral regurgitation underwent transesophageal color Doppler examination, and the diameter of regurgitant jet at its origin was measured. Both right and left cardiac catheterizations were performed within 24 hours of Doppler studies, and angiographic grading of mitral regurgitation and regurgitant stroke volume were evaluated. There was a close relation between the jet diameter at its origin measured by transesophageal Doppler color flow imaging and the angiographic grade of mitral regurgitation (r = 0.86, p less than 0.001). A jet diameter of 5.5 mm or more identified severe mitral regurgitation (grade III or IV) with a sensitivity of 92%, specificity of 92%, and positive and negative predictive values of 88% and 95%, respectively. In 31 patients with isolated mitral regurgitation, the jet diameter correlated well with the regurgitant stroke volume determined by a combined hemodynamic-angiographic method (r = 0.85, p less than 0.001). A jet diameter of 5.5 mm or more identified a regurgitant stroke volume of 60 ml or more with a sensitivity of 88%, specificity of 93%, and positive and negative predictive values of 94% and 87%, respectively. CONCLUSIONS The regurgitant jet width at its origin measured by transesophageal Doppler color flow imaging provides a simple and useful method of measuring the severity of mitral regurgitation, and it may allow differentiation between mild and severe mitral regurgitation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 137 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3