How does angioplasty work? Serial analysis of human iliac arteries using intravascular ultrasound.

Author:

Losordo D W1,Rosenfield K1,Pieczek A1,Baker K1,Harding M1,Isner J M1

Affiliation:

1. Department of Medicine, St. Elizabeth's Hospital, Boston, MA 02135.

Abstract

BACKGROUND Previous studies regarding the mechanism by which balloon angioplasty increases luminal patency have generally used animal models or postmortem specimens from occasional fatal cases of angioplasty performed in human patients. In either case, conclusions regarding participatory mechanisms have relied exclusively on nonserial, postangioplasty histopathological examination. METHODS AND RESULTS In the present study, intravascular ultrasound examination was performed before and after balloon angioplasty in 40 consecutive patients with iliac artery stenoses. The areas of the arterial wall, plaque, lumen, and areas resulting from angioplasty-induced plaque fractures were measured immediately after angioplasty in vivo and compared with findings recorded immediately before angioplasty. Angioplasty increased luminal cross-sectional area (CSA) from 11.5 +/- 0.6 mm2 before angioplasty to 25.4 +/- 1.2 mm2 after angioplasty (p = 0.0001). CSA of the portion of the postangioplasty neolumen contained within angioplasty-induced plaque fractures measured 10.0 +/- 0.8 mm2; the neolumen excluding the area contributed by these plaque fractures measured 15.4 +/- 0.8 mm2. Thus, the area contained within plaque fractures accounted for 10.0 mm2 (71.9%) of the 13.9-mm2 increase in luminal CSA after angioplasty. Analysis of CSA occupied by atherosclerotic plaque disclosed that plaque CSA decreased from 33.8 +/- 1.8 mm2 before angioplasty to 22.5 +/- 1.5 mm2 after angioplasty (p = 0.0001). Plaque CSA was thus reduced ("compressed") by 11.3 +/- 1.1 mm2. Total artery CSA increased ("stretched") slightly from 45.3 +/- 2.6 mm2 before angioplasty to 47.8 +/- 2.0 mm2 after angioplasty (p = 0.0025). CONCLUSIONS In vivo analysis of iliac stenoses by intravascular ultrasound immediately before and after angioplasty demonstrates that plaque fractures and "compression" of atherosclerotic plaque are the principal factors responsible for increased luminal patency resulting from balloon angioplasty. "Stretching" of the arterial wall provides an additional, but minor, contribution.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference69 articles.

1. Perkutane Rekanalisation chronischer arterieller Verschlüsse mit einem neuen Dilatationskatheter

2. Die perkutane Rekanalisation chronischer arterieller Verschlüsse (Dotter-Prinzip) mit einem neuen doppellumigen Dilatationskatheter

3. Gruentzig AR Myler RK Hanna ES: Coronary transluminal angioplasty. (abstract) Circulation 1977;56(suppl III):IlI-84

4. Gruentzig AR Turina MI Schneider JA: Experimental percutaneous dilatation of coronary artery stenosis. (abstract) Circulation 1976;54(suppl II):II-81

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3